The lamp housing is designed to contain these fragments, but use caution when removing the   
lamp housing. Before replacing the lamp, clean the lamp compartment and dispose of cleaning 
materials. Make sure to wash your hands after lamp replacement. This product has a lamp, which 
contains a very small amount of mercury. Dispose of it as required by local, state or federal 
ordinances and regulations. For more information see www.eiae.org. 
 
 
Carefully remove the lamp housing. Dispose of the lamp in  
   an environmentally proper manner. 
 
Install the new lamp housing and tighten the screws. 
 
Re-attach the lamp connector to the projector.  
  The locking tab should engage when the connector is fully   
  plugged in. 
 
10 Replace the lamp door. 
 
11 Replace the base or ceiling mount plate, if necessary.   Service 
menu 
 
12 Plug in the power cord and press the Power button 
    on the remote or keypad to turn the projector back on. 
 
13 To reset the lamp hour timer, navigate to the  
    Settings>Service menu and select Reset  
    Lamp Hours
. See page 21 for details. 
 
 
Appendix 
 
Red LED behavior and projector errors 
If the projector is not functioning properly and the LED is blinking red, consult Table 4 to 
determine a possible cause. There are two-second pauses between the blinking cycles. Visit 
Knoll System’s website for more details on the red LED error codes. 
 
Table 4: LED Behavior 
Red LED Behavior Explanation 
Red LED Behavior 
Explanation 
 
One (1) blink 
The lamp won’t strike after five (5) attempts. Check the lamp and lamp door installations for 
loose connections. 
 
 
Two (2) blinks 
The lamp counter hours have exceeded lamp life hours. Replace the lamp and reset the lamp 
hours counter. 
 
 
Three (3) blinks 
The projector has shutdown. Check to see if the lamp door is open. If the lamp door is closed, 
toggle off the projector and wait one minute and then toggle the projector on again. If the 
lamp does not strike after one minute, replace the lamp. Contact Technical Support (see page 
22) for repair if replacing the lamp does not solve the problem. 
 
Four (4) blinks 
The fan has failed. Contact Technical Support for repair or replacing the fan. 
 
Five (5) blinks 
The projector is overheating. Check for a blocked air vent. Contact Technical Support (see page 
14) for repair if clearing the air vents does not solve this problem.