Jacuzzi j-300 j-345 User Manual

Page of 64
13
J-300
north american J-335, J-345, J-355, J-365 and J-375 Models (60 hz)
240V/40A*
240V/50A**
240V/60A***
Circuit Breaker (2-Pole):
40A
50A
60A
Number of Wires:
3
3
3
Frequency:
60 Hz
60 Hz
60 Hz
Current Draw:
26A
36A
45A
*  In 40A configuration, the heater will not operate while either jets 
pump is running in high speed. Note: pump 2 runs only in high 
speed.
**  In 50A configuration, the heater will not operate while both jets 
pumps are running in high speed. This is the factory setting. 
Note: pump 2 runs only in high speed.
***  In 60A configuration the heater will operate while both jets pumps 
are running in high speed.
north american J-315 and J-325 Convertible Models (60 hz)
120V/15A†
240V/30A†
240V/40A
Circuit Breaker:
15A, 1-Pole
30A, 2-Pole
40A
2-Pole
Number of Wires:
3 (15A GFCI 
Cord US 
Only*)
4 (Hard Wire 
Only)
4 (Hard Wire 
Only)
Frequency:
60 Hz
60 Hz
60 Hz
Current Draw:
12A
21A
30A
*  all Canadian spas must be hard wired per Csa Canadian standards 
(page 8).
  In 15A/30A configuration, the heater will not operate while the jets 
pump is running in high speed. The factory setting is 120V/15A.
  In 40A configuration, remove jumper JP1-2 on the board, to allow the 
heater 
to operate while the jets pump is running in high speed.
  Caution (For 4-wire 240 vaC Heater operation): Move the red 
wire on the main terminal strip (TB1) from position #1 to position #3. 
Make certain wires are connected exactly as shown in Figure D (Page 
17) before applying power. Failure to do so will result in damage to the 
circuit board and/or related components and void the manufactures  
warranty.