Contec SPI-8451-LLVA User Manual

Page of 123
6. RAID Controller 
 
 
 
SPI-8451-LLVA, SPI-8452-LLVA, SPI-8451-LVA 
51 
Rebuilding a mirrored Array 
Rebuild Array <5> Menu option is necessary to recover from an error in a mirrored disk array. You will 
receive an error message when booting your system from the FastTrak BIOS. 
CAUTION
 
 
 
Drives MUST be replaced if they contain any physical errors. 
 
Follow these steps BEFORE using the Rebuild Array menu option: 
1.  On boot up, the FasTrak100-Lite Startup BIOS will display an error message identifying which drive 
has failed. 
2.  Press <Ctrl-F> keys to enter FastBuild Main Menu. 
3.  Select submenu Define Array <3>. 
4.  Select the failed array and identify the Channel and ID of the failed drive. 
5.  Power off and physically remove the failed drive. 
6.  Replace the drive with an identical model. 
7.  Reboot the system and enter the FastBuild™ Main Menu. 
8.  Select the <5> Rebuild Array option. The following screen will appear. 
 
FastBuild (tm) Utility 1.xx (c) 1996-2001 Promise Technology, Inc. 
 
[ Rebuild Array Menu ] 
    Array No          RAID Mode 
Total Drv        Capacity(MB)      Status 
  Array 1         Mirror          2            16126        Critical 
    Array 2                  ——                    ——                      ——                  —— 
    Array 3                  ——                    ——                      ——                  —— 
    Array 4                  ——                    ——                      ——                  —— 
 
[ Keys Available ] 
[
↑] Up [↓] Down    [ESC] Exit    [Enter] Select 
9.  Highlight the array whose Status is Critical. 
10.  Press [Enter]. The following screen will then appear. 
 
FastBuild (tm) Utility 1.xx (c) 1996-2001 Promise Technology, Inc. 
 
[ Rebuild Array Menu ] 
    Array No      RAID Mode      Total Drv      Capacity(MB)        Status 
  Array 1 
    Mirror         2         16126           Critical 
     
 
    Stripe Block: Not Available 
 
[ Select Drive for Rebuild ] 
    Channel:ID        Drive Model                Capacity (MB) 
   1 : Slave     QUANTUMCR8.4A 
    8063 
 
 
 
[ Keys Available ] 
[
↑] Up [↓] Down     [ESC] Exit    [Enter] Select 
11.  Under [Select Drive for Rebuild], highlight the replacement drive.