Campbell Hausfeld HU3501 User Manual

Page of 24
  Gauge of Cord 
 
16 
14 
10
 
 
     Extension cords for 120V/10 Amp Unit
  Length of Cord (ft) 
 
25 
50 
100
HU3501
3
Assembly
ASSEMbLY TOOLS REqUIRED
Tools (not provided) for assembly:
-  2 14mm wrench or socket wrench 
-  2 17mm wrench or socket wrench
FOOT ASSEMbLY (FIGURE 1)
Foot assembly kit includes:
-  1 rubber foot
-  1 bolt
-  2 washers
-  1 nut
WHEEL ASSEMbLY (FIGURE 2)
Wheel assembly kit includes:
-  2 wheels*
-  2 axle bolts*
-  2 lock washers*
-  2 nuts*
The items marked with an asterisk (*) 
were shipped loose with the unit.
1.  Wheel has an offset hub. With offset 
hub facing axle iron, assemble axle bolt 
through holes in wheel and axle iron.
2.  Place lock washer on axle bolt. Then 
tighten nut securely to threaded 
part of axle bolt.
3.  Repeat procedure with other side.
HANDLE ASSEMbLY (FIGURE 3)
 
Never use the 
  handle to lift the 
unit completely off the ground. only 
use the handle to lift one end so the 
wheels may be used to move the unit.
Handle assembly kit includes:
-  1 handle
-  2 bolts
1.  Insert ends of handle into tube 
shaped brackets on tank.
2.  Align screw holes.
3.  Thread screw into hole until tight.
Installation
LOCATION
It is extremely important to install the 
compressor in a clean, well ventilated area 
where the surrounding air temperature 
will not be more than 100°F.
A minimum clearance of 18 inches between 
the compressor and a wall is required 
because objects could obstruct air flow.
 
Do not locate the 
  compressor air inlet 
near steam, paint spray, sandblast areas 
or any other source of contamination. This 
debris will damage the motor
Household use only. Store indoors.
ELECTRICAL INSTALLATION
1.  Check and tighten all bolts, fittings, 
etc., before operating compressor.
2.  Operate compressor in a ventilated 
area so that compressor may be 
properly cooled.
3.  Compressor should be located where 
it can be directly plugged into an 
outlet, but if this is not possible, an 
extension cord may be used. It should 
be selected using the extension cord 
chart on page 3 as a guide.
4.  To avoid loss of power and 
overheating, it is better to use 
additional air hose instead of 
extension cords to reach work area.
WIRING
1.  Local electrical wiring codes 
differ from area to area. Source 
wiring, plug and protector must 
be rated for at least the amperage 
and voltage indicated on motor 
nameplate, and meet all electrical 
codes for this minimum .
2.  Use a slow blow fuse type T or a 
circuit breaker.
 
 overheating, short  
   circuiting and fire 
damage will result from inadequate 
wiring, etc.
 
All wiring and 
  electrical 
connections should be performed by a 
qualified electrician. installation must 
be in accordance with local codes and 
national electrical codes.
NOTE: 120 volt, compressor can be 
operated on a 120 volt, 15 amp circuit 
under the following conditions:
a. No other electrical appliances or 
lights are connected to the same 
branch circuit.
b. Voltage supply is normal.
c. Extension cords are of the 
minimum gauge specified in this 
instruction manual.
d. Circuit is equipped with a 15 amp 
circuit breaker or a 15 amp slow 
blow fuse type T.
3.  If above conditions cannot be met 
or if nuisance tripping of current 
protection device occurs, it may be 
necessary to operate compressor 
from a 120 volt, 20 amp circuit.
  Power cord 
White 
Line 
No
  Motor cord 
White 
Load 
No
  Power cord 
Black 
Line 
Yes
  Motor cord 
Black 
Load 
Yes
✽ 
Wire and Terminal Guide
  Wire 
Color 
Terminal 
Hot
(✽) When the unit is not in operation
www.chpower.com
 
Wheel
Axle Bolt
Lock 
Washer
Nut
Figure 2 - Wheel assembly
Bolt
Handle
Tank
Figure 3 - Handle Assembly
Rubber Foot
Washer
Bolt
Washer
Nut
Figure 1 - Rubber foot installation