Bunn EASY CLEAR H5E User Manual

Page of 24
13
SERVICE (cont.)
Safety Overfl ow Switch
Location:
The safety overfl ow switch is located inside the rear of 
the dispenser inside the copper overfl ow cup.
For testing or removal of the safety overfl ow switch, 
access may also be needed by removing the two screws 
attaching the electronic control assembly to its mount-
ing bracket.
Test Procedure:
1.  Once voltage is verifi ed at the power source, check 
for continuity across the safety overfl ow switch 
red wires only until the plastic fl oat is raised and 
check that continuity returns when the plastic fl oat 
is again lowered.
If continuity is present as described, reconnect each 
of the red wires to the black wires, the safety overfl ow 
switch is operating properly.
If continuity is not present as described, replace the 
safety overfl ow switch.
FIG. 13a SAFETY OVERFLOW SWITCH
FIG. 13c SAFETY OVERFLOW WIRING
RED to BLK Wire from 
Terminal Block
RED to BLK Wire from Elec-
tronic Control #3
P4093
P1777
Removal and Replacement:
1.  Disconnect the black wires from the safety overfl ow 
switch.
2.  Remove the nut beneath the copper overfl ow cup.
3.  Remove the entire switch assembly from the cup.
4.  Place the new switch assembly into the cup, wires 
fi rst. Make sure that a gasket is in place around the 
threaded switch stem.
NOTE - The magnets must be at the top of the fl oat and 
there must be NO stainless steel washers installed for 
the safety overfl ow switch to operate properly.
5.  Install the nut beneath the copper overfl ow  cup.  
Be sure not to overtighten.
6.  Reconnect the wires, FIG. 6.
P1993
FIG. 13b OVERFLOW PROTECTION  SWITCH
42311 071310
H 10
H 5