SERVICE (cont.)
Tank Heater
Location:
The tank heater is located in the tank lid.
Test Procedure:
1.  Disconnect the dispenser from the power source.
2.  Check the voltage across the terminals of the tank 
heater with a voltmeter. Connect the dispenser to 
the power source. The indication must be:
 
a.) 100 to 120 volts ac for 100 to 120 volt models 
or
 
b.) 200 to 240 volts ac for 200 to 240 volt models
 or
 
c.) 230 volts ac for 230 volt models.
3.  Disconnect the dispenser from the power source.
If voltage is present as described, proceed to #4.
If voltage is not present as described, replace the tank 
heater.
FIG. 16a TANK HEATER
FIG. 16c TANK HEATER WIRING
BLK to Limit 
Thermostat
BLU to Control 
Board Relay
P1780
P4093
4.  Remove the tank heater from the tank lid and in-
spect it for cracks in the sheath.
If the sheath shows no sign of damage, proceed to #5.
If the sheath is damaged, replace the tank heater.
5.  Check for continuity across the tank heater termi-
nals.
If continuity is present as described, reinstall the tank 
heater. The tank heater is operating properly.
If continuity is not present as described, replace the 
tank heater.
Removal and Replacement:
1.  Remove the wires to the tank heater.
2.  Remove the 8-32 nuts from the tank heater fl ange.
3.  Remove the tank heater.
4.  Inspect the tank heater gasket and replace if neces-
sary.
5.  Securely install the new tank heater. Be certain of 
a watertight seal.
6.  Reconnect the wires, FIG. 10.
P1993
FIG. 16b TANK HEATER
42311 071310
  1800W-120V  
 
0
7.44   - 
0
8.67 
  4000W-240V  
 
13.43   - 15.51 
  4000W-208V  
 
10.09   - 11.99 
  6000W-240V  
 
0
8.85   - 10.23 
  6000W-208V  
 
0
6.67   - 
0
7.70 
      HEATER 
 
        RESISTANCE
TERMINAL TO SHEATH - INFINITE (OPEN)
H 10
H 5