Bunn CDS-3 User Manual

Page of 34
30
SERVICE (cont.)
DOOR SWITCH
FIG. 28 DOOR SWITCH
P1934
Location:
The door switch is located on the right side panel 
under the housing top cover.
Test Procedures:
1.  Disconnect the dispenser from the power source.
2.  Disconnect the twelve pin connector (J1) from the 
control board.
3.  Check continuity between pins 8 & 9 on the wiring 
harness using an ohmmeter. Continuity must be 
present when the door is closed. Continuity must 
not be present when the door is open.
4.  Reconnect the twelve pin connector to the control 
board.
5.  Gain access to the door switch using steps listed 
in Removal and Replacement.
6.  Disconnect the wires from the door switch.
7.  Check continuity between the N.O. and COM. ter-
minals of the switch using an ohmmeter. Continuity 
must  be  present  when  the  actuator  is  engaged. 
Continuity must not be present when the actuator 
is released.
If continuity is present as described, refer to wiring 
diagram and check the dispenser wiring harness.
If  continuity  is  not  present  s  described,  replace  the 
door switch.
Removal and Replacement:
1.  Disconnect the dispenser from the power source.
2.  Remove the hopper assembly from the dispenser.
3.  Remove the dispenser from the CDS machine and 
place it on a flat work surface.
4.  Disconnect the door lamp cord from the lamp con-
nector.
5.  Remove the two #8-32 screws securing the door 
hinge to the dispenser housing.
6.  Carefully pull the door forward until the door support 
arms come completely out of the dispenser housing 
and set aside.
7.  Remove the six #8-32 truss head screws securing 
the rear cover to the dispenser housing.
8.  Remove the six #8-32 round head screws securing 
the front of the housing to the side panels.
9.  Remove the six #8-32 truss head screws securing 
the back of the housing to the side panels.
10. Carefully lift and spread the housing to remove it 
from the rest of the dispenser.
11. Remove  the  door  switch  actuator  from  the  nylon 
standoff.
12. Noting the orientation of the door switch, remove the 
two #6-32 screws and the nylon standoff securing the 
switch mounting bracket to the dispenser housing. 
Remove the switch.
13. Attach the new door switch taking care to orient the 
switch correctly in the mounting bracket and secure in 
place with two #6-32 screws and nylon standoff.
14. Reconnect the wires to the door switch. Refer to Fig. 
29.
15. Install the door switch actuator orienting the notched 
side against the right side housing panel. Refer to 
Fig. 28.
16. Reassemble the dispenser top housing, rear panel, 
and door assembly to the dispenser.
FIG. 29 DOOR SWITCH TERMINALS
P1908
ORA to Control 
Board (J1-9)
GRN to Control 
Board (J1-8)
29793 061599