Datalogic Scanning SR User Manual

Page of 124
14
PowerScan
®
 RF Scanner
Depth of Field
There are currently four different range models for the scanner. 
Depending upon the model type of your scanner, you’ll need to hold 
the unit at a given distance from the bar code to achieve optimum scan-
ning results. The following diagrams provide depth of field informa-
tion for each of the models when scanning grade A, Code 39 bar codes: 
Standard Range (SR), High Density (HD), Long Range (LR) and Extra 
Long Range (XLR).
Definition of
a "mil"
A "mil" is equal to 0.001 inches. In the context of the illustrations in this 
section, a mil represents the minimum bar code element width. Thus a 
5 mil bar code would have a minimum element width of 5 mils (or 
0.005 inches).
Figure 7. Depth of Field (SR)
NOTE
Measurements are based on SR models set with the
standard 28° scan width (as opposed to the Half
Angle setting of 14°). Reference the Programming
Manual for more information about the Half Angle
feature.
Specifications are subject to change without notice.
Depth of Field
Paper Labels (SR decoded model, Code 39)
 
0
20 mil
15 mil
10 mil
5 mil
CENTIMETERS
FEET
FRONT OF SCANNER
10
1
2
3
4
5
20
30
40
50
60
70
80
90
100
110
120
130
140
150
160
170
40 mil
7.5 mil
55 mil