FMI (v)g42hr-50hr User Manual

Page of 16
www.fmiproducts.com
109493-01R
14
  WARNING:  Fireplaces 
equipped  with  glass  doors 
should  be  operated  only  with 
doors fully opened or doors fully 
closed. Doors, if left partly open, 
may draw gas and flame out of 
the  fireplace  opening  creating 
risks of both fire and smoke.
Cleaning Glass
Clean  glass  with  any  commercial  glass 
cleaner or soap and water. Do not use any 
abrasive material to clean glass. Do not clean 
glass with any cool water if glass is still hot 
from the fire and smoke.
A gas line or gas log lighter may be installed 
for the purpose of installing a vented or vent-
free decorative gas appliance incorporating an 
automatic shutoff device and complying with 
the Standard for Decorative Gas Appliances 
for  Installation  in  Vented  Fireplaces, ANSI 
Z21.60  or  American  Gas Association  draft 
requirements for Gas Fired Log Lighters for 
Wood Burning Fireplaces, Draft NO. 4 dated 
August, 1993.
If you wish to install an unvented (vent-free) 
gas log set, only unvented gas log sets which 
have been found to comply with the standard 
for unvented room heaters, ANSI Z21.11.2 are 
to be installed in this fireplace.
OUTSIDE AIR AND DAMPER 
HANDLE OPERATION
The damper handle, which opens and closes 
the damper blade, is located in the upper front 
face of the fireplace. Pushing the handle for-
ward and up through the keyway slot will free 
damper blade to automatically open. Pushing 
the handle forward and down will lock damper 
blade closed (see Figure 25).
The outside air kit lever is located at the left 
and right hand sides of fireplace (see Figure 
26). Lifting lever up will free the outside air 
door  to  open.  Pulling  lever  down  will  lock 
the door. 
operaTion and MainTenance guidelines
Continued
Figure 25 - Operating Damper Handle
Damper 
Weight
To Close 
Damper
To Open 
Damper
Damper 
Weight
Open Position
Closed Position
Figure 26 - Outside Air Kit Lever
  WARNING:  Risk  of  fire! 
Replace grate with FMI PROD-
UCTS,  LLC  model  109496-01 
(42" Models) or 109496-02 (50" 
Models)  grate  only.  This  grate 
has been designed to keep the 
operation of your fireplace safe 
and efficient.