Fujitsu fs-1108au-fs1108mu User Manual

Page of 60
 
4 8  
13. Troubleshooting
 
Symptom
 
Cause
 
Remedy
 
The keyboard and mouse are connected 
in reverse. 
(PS/2 only)
 
Connect the keyboard and the 
mouse correctly to the server and 
KVM Switch.
 
The Hotkey mode is not released.
 
Press <Enter> or <Esc>.
 
Poor connection/defective cable.
 
Confirm that the connector is 
connected properly. 
Replace the keyboard or mouse.
 
An unsupported keyboard or mouse is 
connected.
 
Replace the unsupported keyboard 
or mouse with one that is 
supported.  
 
The keyboard and mouse are connected 
to both the PS/2 console and the USB 
console.
 
Remove the mouse and keyboard 
connection from either the PS/2 
console or the USB console. 
When a keyboard and mouse are 
both connected to a PS/2 console 
and a USB console, the USB side 
is given priority and the PS/2 side 
does not operate.
 
Keyboard and 
mouse operation 
are not normal/ 
unresponsive. 
 
The keyboard type (country code) is set 
but the keyboard does not operate 
according to the setting.
 
When cascade connections on the 
slave side are used for a previous 
KVM Switch model, the DIP switch 
setting on the previous KVM Switch 
model is enabled. Change the DIP 
switch setting.
 
An unsupported mouse is used.
 
Replace the unsupported mouse 
with a mouse that is supported.
 
The mouse button 
does not operate.
 
The appropriate mouse driver is not 
installed.
 
Install the correct mouse driver.
 
Poor image quality. 
(Ghosts, blurry 
letters, etc.)
 
Poor connection/defective cable.
 
Confirm that the connector is 
connected properly. 
Use a different cable. If the problem 
goes away, exchange the defective 
cable with a good one.
 
The resolution is different.
 
Set the resolution to the correct 
resolution or adjust the resolution 
settings on the monitor.
 
Image is not 
centered on screen 
or does not display 
when the screen is 
changed.
 
Unsupported monitor/ not synchronized.
 
Connect a monitor that is 
supported. 
Adjust the monitor.
 
AutoScan changing
 
cycle is not normal.
 
The changing cycle has not been 
adjusted. 
(10 seconds is the default setting)
 
Use <↑> and <↓> to adjust the 
settings.