Campbell Hausfeld VT6315 User Manual

Page of 24
3
VT6315, VT6358, VT6361
www.chpower.com
Operating Instructions
Introduction
Refer to Figure 1 to locate the following 
items .
Pressure switch - Auto/Off Switch - In 
the AUTO position, the compressor 
shuts off automatically when tank 
pressure reaches the maximum preset 
pressure . After air is used from the tank 
and drops to a preset low level, the 
pressure switch automatically turns the 
motor back on . In the OFF position, the 
compressor will not operate . This switch 
should be in the OFF position when 
connecting or disconnecting the power 
cord from the electrical outlet .
When the pressure switch turns the 
motor off you will hear air leaking out 
of the pressure switch unloader valve 
for a short time . This releases the air 
pressure from the discharge tube and 
allows the compressor to restart easier .
Regulator - The regulator controls the 
amount of air pressure released at the 
hose outlet .
Assembly
HANDLE ASSEMBLY - Handle may be 
pre-assembled on some units .
Insert four handle screws through holes 
in handle and tighten to tank baseplate 
(See Figure 2) .
FOOT ASSEMBLY
The items marked with an asterisk (*) 
were shipped loose with the unit (See 
Figure 3) .
1 .  Tilt unit to allow access to front foot 
and secure properly to ensure unit 
does not tip over .
2 .  Insert bolt through foot and bracket . 
The foot should be on the lower side 
of bracket .
3 .  Tightly secure with the lock nut . 
Repeat on opposite side .
ASMe Safety Valve - This valve 
automatically releases air if the tank 
pressure exceeds the preset maximum .
Discharge tube - This tube carries 
compressed air from the pump to the 
check valve . This tube becomes very hot 
during use . To avoid the risk of severe 
burns, never touch the discharge tube .
 
To avoid the risk of    
  severe burns, never 
touch the discharge tube.
Check valve - One-way valve that 
allows air to enter the tank, but 
prevents air in the tank from flowing 
back into the compressor pump .
handle - Designed to move the 
compressor .
 
Never use the    
  handle to lift the 
unit completely off the ground. Handle 
is intended only for pushing or pulling 
product.
Belt Guard - Covers the belt, motor 
pulley and flywheel .
 
Never  
  operate
compressor without a 
beltguard. This unit can 
start automatically without 
warning. Personal injury or property 
damage could occur from contact with 
moving parts.
Tank Drain Valve - This valve is located 
on the bottom of the tank . Use this 
valve to drain moisture from the tank 
daily to reduce the risk of corrosion .
Reduce tank pressure below 10 psi,  
before opening drain valve .
Tank Pressure Gauge - Indicates 
amount of air pressure stored in tank .
hose Pressure Gauge - Indicates 
amount of air pressure in hose used to 
operate tools . This pressure is increased 
or decreased by the regulator .
Drain
Petcock
Handle
Discharge Tube
Check Valve
Belt Guard
Tank
Breather/
Dipstick
& Oil Fill 
Hole
Intake Filter
Hose 
Pressure
Gauge
Pressure
Switch
Figure 1
Figure 2
Tank Baseplate
Handle Screw
Handle
Figure 3
Foot*
Wheel*
Lock Nut*
Shoulder Bolt*
Nut*
Bolt*