Jacuzzi led series j-230 User Manual

Page of 43
page 
6.0 Power Requirements
Jacuzzi
®
 spas are designed to provide optimum performance and flex-
ibility of use when connected to the maximum electrical service listed in 
the tables below.  If you prefer, your dealer can perform a minor circuit 
board modification to allow your spa to accept an electrical service other 
than the factory setting.
US / Canada J-230 2-Pump Model (60Hz)
 
240V/40A* 
240V/50A** 
240V/60A***
Voltage: 
240 VAC 
240 VAC 
240 VAC
# of Wires: 
3
Frequency: 
60Hz 
60Hz 
60Hz
Current Draw: 
26A 
36A 
45A 
Circuit Breaker: 
40A, 2-Pole 
50A, 2-Pole 
60A, 2-Pole
 
 
*  In 40A configuration, the heater will not operate while either jets 
pump is running in high speed. Note: pump 2 runs only in high speed.
**  In 50A configuration, the heater will not operate while both jet pumps 
are running in high speed. Note: pump 2 runs only in high speed.  
This is the factory setting.
*** In 60A configuration, the heater will operate while both jet pumps are
 
running in high speed.  Note: pump 2 runs only in high speed. 
US/Canada J-210/J-220 1-Pump Convertible Model (60Hz)
 
120V/15A* 
240V/30A* 
240V/40A**
Voltage: 
120 VAC 
240 VAC 
240 VAC
# of Wires: 
3 (15A GFCI Cord 
4
 
US only*)
Frequency: 
60Hz 
60Hz 
60Hz
Current Draw: 
12A 
21A 
30A 
Circuit Breaker: 
15A, 1-Pole 
30A, 2-Pole 
40A, 2-Pole
For 240 VAC Heater Operation: Move the red wire on the main terminal 
strip (TB1) from position #1 to position #3. Make certain wires are con-
nected exactly as shown in Figure-D (page 12) before applying power.  
Failure to do so will result in damage to the circuit board and/or related 
components and void the manufacturer’s warranty.  
*All Canadian spas must be hard wired (120 VAC or 240 VAC) per 
CSA Canadian standards. (page 4).
*  In 15A/30A configuration, the heater will not operate at the same 
time as the high-speed jets pump.  The factory setting is 120V/15A.
**  In 40A configuration, remove the jumper JP1 #1-2 on the circuit 
board to allow the heater to operate at the same time as the 
 
high-speed jets pump (page 32).