14.2 Panel Displays SN2
open or shorted sensor (heater disabled). The temperature 
sensor is not functioning. Contact your authorized Jacuzzi 
dealer or qualified service technician.
14.3 Panel Displays FL1
Pressure switch is not closed when the pump is activated. 
Heater is deactivated. Proper flow of water is inhibited or 
pressure switch has malfunctioned. Check for proper water 
level, pump is primed and/or clogged filter. Contact your authorized 
Jacuzzi dealer or qualified service technician.
14.4 Panel Displays FL2
Pressure switch is closed while pump is deactivated. Contact 
your authorized Jacuzzi dealer or qualified service techni-
cian.
14.5 Panel Displays COL
Cool Condition - Temperature has dropped 20°F (°C) 
below the current set temperature. The pump and heater 
have been activated to bring the temperature to within 5°F 
(8°C) of the set temperature. No corrective action is required. Note: 
during cold periods, you may consider increasing the number of filtration 
cycles (page 23).
14.6 Panel Displays ICE
Freeze Protection - A potential freeze condition has been 
detected.  No action is required.  The pump and heater will 
operate to circulate and warm water through the plumbing 
until spa is out of danger.  See “Winterizing” (page 26).
14.7 Panel Displays OH
Water temperature is above acceptable limits. Do not enter 
spa!  Water temperature has reached 112˚F (44˚C) and the 
low speed pump has activated to circulate water through 
heater.  Contact your authorized Jacuzzi dealer or qualified service 
technician.
14.8 Panel Displays  - - -
The safety “Watchdog” software has been triggered and 
the spa is deactivated. A problem has been detected which 
could cause damage to the spa or its components. Contact 
your authorized Jacuzzi dealer or qualified service technician.