J-200
it. For optimum filtration benefits, always leave this valve in position A 
when the spa is covered and select positions B or C for maximum jet per-
formance during spa use.
10.7  air Controls
Certain jet systems have their own air control. Each control  
introduces air into the water lines that supply that specific jet 
group. Simply turn the air control of choice counterclockwise 
to open or clockwise to close. To minimize heat loss, all air controls 
should be closed when the spa is not in use.
10.8  optional audio system (J-230 to J-280)
Spas equipped with the optional Jacuzzi audio system 
offer enhanced enjoyment. These models include 
an integrated AM/FM/CD receiver with high-quality marine speakers for 
unsurpassed sound quality and long-life.
11.0  automatic Filtration Cycles
The control system activates a programmable “Standard” or “Economy” 
filtration cycle to remove debris from your spa. These cycles use the low 
speed jets pump 1 and filter cartridge to quickly clear “skim” the water 
of debris and minimize their “bathtub ring” affect while the spa is in use 
or during a programmed filter cycle. Models equipped with the optional 
24-hour circulation pump offer the added benefit of 24-hour filtration for 
pennies a day! The circulation pump is not programmable. Apart from their 
filtration benefit, each filtration mode also effects the operation of the spa 
heater. Refer to Sections 11.1 and 11.2 for details.
11.1 
standard Filtration/heating Modes For models without 
Circulation pump option (all models)
Standard filtration/heating modes (F1-F3) are typically selected by 
customers in cold climates where heat up times are extended due to lower 
ambient temperatures. In either of these modes, the water temperature is 
regulated by the set temperature, low-speed jets pump 1 and heater which 
turns on as needed. After the programmed set temperature is reached, the 
heater and low speed pump turn off, only to turn back on during a heat call 
or during the next programmed filtration/heating cycle.
11.2 
standard Filtration/heating Modes For models with 
Circulation Pump option (J-230, J-270 and J-280 only)
Standard filtration/heating modes (F0-F3) are typically selected by 
customers in cold climates where heat up times are extended due 
to lower ambient temperatures. In either of these modes, the water 
temperature is regulated by the set temperature, 24-hour circulation 
pump and heater which turns on as needed. After the programmed set 
temperature is reached, the heater turns off and the circulation pump 
continues to operate 24-hours to filter and clean your spa.