Hanna Instruments hi 9060 User Manual

Page of 2
w w w . h a n n a i n s t . c o m
Hanna Instruments reserves the right to modify the design, construction and
appearance of its products without advance notice.
WARRANTY
Dear Customer,
Thank you for choosing a Hanna product. This manual will
provide you with the necessary information for correct opera-
tion. Please read it carefully before using the meter. If you
need additional technical information, do not hesitate to e-
mail us at tech@hannainst.com.
This instrument is in compliance with the      directives.
PRELIMINARY EXAMINATION
GENERAL DESCRIPTION
FUNCTIONAL DESCRIPTION
This Instrument is in
Compliance with CE
Directives
SPECIFICATIONS
Instruction Manual
HI 9060
Portable Waterproof
 Microprocessor-based
Thermistor
Thermometer
Remove the instrument from the packing material and
examine it carefully to make sure that no damage has
occurred during shipping. If there is any noticeable damage,
notify your Dealer or the nearest Hanna Office.
Note: Save all packing materials until you are sure that the
instrument functions correctly. Any defective item must
be returned in the original packaging together with
the supplied accessories.
Range
Resolution
Accuracy
Typical EMC
Deviation
Display
Battery Type
Life
Probe 
(included)
Environment
Dimensions
Weight
1. Battery cover
2. Temperature probe connector
3. Liquid Crystal Display
4. ON/OFF Key
5. Measuring unit selection key
6. HOLD measurement key
7. HI/LO values reset key
HI 9060 is a waterproof, microprocessor-based, thermistor
thermometer, ideal for use in wet and humid environments.
The meter is also provided with low battery detection and
BEPS (Battery Error Preventing System), which turns the
unit off when the batteries are discharged avoiding errone-
ous readings caused by low battery level.
HI 9060 features include a dual-level LCD for simultaneously
displaying of maximum and minimum measured tempera-
tures, °C/°F selection button and hold function.
Each meter is supplied complete with HI 765BL temperature
probe, 4 x 1.5V AA batteries and instruction manual.
1. Current temperature value
2. HOLD indicator
3. Low Battery indicator
4. Minimum temperature value
5. Maximum temperature value
6. Measuring scale, °C or °F
CE DECLARATION OF CONFORMITY
ISTR9060       01/03
All Hanna Instruments meters are warranted for two years against
defects in workmanship and materials when used for their intended pur-
pose and maintained according to instructions. Sensors and probes are
warranted for a period of six months.
This warranty is limited to repair or replacement free of charge.
Damages due to accidents, misuse, tampering or lack of prescribed main-
tenance are not covered.
If service is required, contact the dealer from whom you purchased the
instrument. If under warranty, report the model number, date of purchase,
serial number and the nature of the failure.
First obtain a Returned Goods Authorization number from the Customer
Service department, then return the instrument with the Authorization #
included along with shipment costs prepaid. If the repair is not covered by
the warranty, you will be notified of the charges.
When shipping any instrument, make sure it is properly packaged for
complete protection.
All rights are reserved. Reproduction in whole or in part is prohibited
without the written consent of the copyright owner, Hanna Instruments
Inc., Woonsocket, Rhode Island, 02895 , USA.
-50.0 to 150.0°C / -58.0 to 302.0°F
0.1°C or 0.1°F
±0.4°C / ±0.8°F
excluding probe error
±1°C / ±2°F, with HI 765BL probe
Dual-line LCD
4 x 1.5V AA (IEC LR6)
approx. 3000 hours of continuous use
HI 765BL with 1 m (3.3') cable
-10 to 50ºC (14 to 122ºF); RH 100%
196 x 80 x 60 mm (7.7x3.1x2.4")
425 g (15 oz) meter only