BBE Sound ars2 User Manual

Page of 16
1.  POWER CORD: USA configuration shown in illustration above.
2.
FUSE: Replace ONLY with same type Fast-blow fuse.
USA, Canada and Japan models:  250Vac, 1/2A Fast-blow
Standard model: 250Vac, .125A Fast-blow
3.  INPUTS: The signal input to the BBE ARS is to be applied to the RCA jacks labeled “IN”,  Refer
to the “CONNECTIONS” pages for proper hook-up.
4. OUTPUTS: The signal output of the BBE ARS is to be taken from the RCA jacks labeled “OUT”.
Refer to the “CONNECTIONS” pages for proper hook-up.
REAR PANEL
4
SPECIFICATIONS
(
0dBu = 0.775mVrms)
Frequency Response ……………………………………process on: program controlled
process off: DC to 20kHz
Absolute noise in process mode ………………………-90dBu below rated max output of 0dBu
THD in process mode …………………………………less than 0.1% @-10dBu level
Input Characteristics
Input Impedance ……………………………………50K Ohms
Nominal Input Level ………………………………-10dBu
Output Characteristics
Minimum load impedance for full output level ……1K Ohm
Nominal Output Level………………………………-10dBu
Maximum Output Level ……………………………+16dBu
Power Requirements
USA / Canada / Japan models………………………100-120Vac, 50/60Hz, 10 Watts
Standard model ……………………………………200-240Vac, 50/60Hz, 10 Watts
AC Line fuse protected…………………………………USA Model: 250Vac  1/2A Fast-blow fuse
Standard Model:  250Vac .125A Fast-blow fuse
Terminations/Connectors ………………………………Gold-plated RCA jacks
Dimensions ……………………………………………16.5"(W) x 8.5"(D) x 1.7"(H)
419mm(W) x 216mm(D) x 43mm(H)
Shipping Weight ………………………………………6.5 lbs.
Note:  Due to continuing product improvement, specifications and design are subject to change without notice.
2
3
4
CAUTION:
FOR CONTINUED PROTEC-
TION AGAINST RISK OF FIRE, REPLACE
ONLY WITH SAME TYPE T63mA, 250V FUSE.
ATTENTION:
UTILISER UN
FUSIBLE DE RECHANGE DE
MEME TYPE DE T63mA, 250V.
AVIS: 
RISQUE DE CHOC ELECTRIC 
NE PAS OUVRIR! 
RISK OF ELECTRIC SHOCK 
DO NOT OPEN
!
230
;
8 WATTS
50/60Hz
®
HUNTINGTON BEACH, CALIFORNIA
MADE IN U.S.A.
IN
OUT
R
L
R
L
full frequency focus
ARS
CAUTION
FUSE
1