MALFUNCTIONS AND THEIR RESOLUTION
Fault
Cause
Remedy
No circular image is obtained 
during viewing.
a) The binoculars are not 
sufficiently adapted to your 
personal interocular distance.
a) Correct the distance between 
the two binocular tubes simply 
by bending the pivot axis more or 
less.
b) The pupils of the viewer are 
not in the exit pupil of the 
binoculars.
b) Correct head, eye and  
binocular position.
c) The position of the eyecups 
does not correspond to correct 
use with and without specta-
cles.
c) Correct adjustment: Wearers 
of spectacles screw the eyecups 
in; when viewing without spec-
tacles: screw eyecups out.
d) The position of left and right 
eyecups is different.
d) Move both eyecups to the 
same position.