Sony E 10-18 mm f/ 4 OSS Lens Manual

Page of 111
4-31
SAL55200 (DT 4-5.6/55-200) (DT 55-200mm F4-5.6)
3. Adjusting Method
1)
Adjust the G10-11 adjustment washer thickness according to the result of step 3) in “2. Checking Method”. (Refer to Table 4-6-1 and
Fig.4-6-2.)
When the focus-shift is a positive value: Increase G10-11 adjustment washer thickness by the amount of focus-shift.
When the focus-shift is a negative value: Decrease G10-11 adjustment washer thickness by the amount of focus-shift.
Note:
And “Curvature of field” is amendable by the variation of the G10-11 adjustment washer.
Part No.
Description
t (mm)
3-279-372-01
G10-11 ADJUSTMENT WASHER
0.05
3-279-372-11
G10-11 ADJUSTMENT WASHER
0.03
3-279-372-21
G10-11 ADJUSTMENT WASHER
0.02
3-279-372-31
G10-11 ADJUSTMENT WASHER
0.10
3-279-372-41
G10-11 ADJUSTMENT WASHER
0.15
Table 4-6-1
Fig.4-6-2
2)
Repeat the check and adjustment until the focus-shift tolerance meets the specification.
Note:
When perform this adjusument, perform “Projective Resolving Power (Curvature of filed) Adjustment” (Refer to page 4-25).
Rear Light
Shield Barrel
G11-13 Barrel Assy
G10-11 Adjustment Washer
A
A