5.1.2. 
 Base Modem   
• 
With  1 RS232 (EFT930P/EFT930G/EFT930W) 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Follow the below instructions to connect the base to the telephone network : 
 
• 
Connect telephone plug C equipped if necessary with user country specific 
telephone plug, to the telephone network D.  
• 
Connect the other end of the wire to the base (socket G).  
• 
Connect the mains power supply wire to the base (socket H). 
• 
If necessary, connect the telephone A. 
(Telephone A is not required for the terminal to operate).  
- France: plug B to the telephone network D through the piggyback plug  
- other countries: telephone is connected to the base through the socket J (RJ-
type connector). 
• 
Connect power supply block F to the mains electrical socket E.  
 
Socket G (=socket J) : TNV-3 circuit: Telecommunication Network Voltage, as per safety 
standard EN 60950-1.  
Socket I : SELV circuit: Since these links are Safety Extra Low Voltage circuits, they must be 
interconnected to units which have interfaces powered by the same type of circuits.  
 
Turn off the terminal prior to connecting the base to the appropriate network. 
 
 
 
Marking
 
A = possible telephone handset 
B = 
telephone connector (country specific) 
C = connection to the telephone network 
D = telephone network socket 
E = mains power socket 
F = power adapter 
G = telephone network - port RJ11 (telephone cable 3m) 
H = power input - 2pole sockets 1 A 
I = RS232 (cash register, local loading tool, etc.) Level RS 232/V28 
J = telephone handset output