APC Symmetra PX SY32K96H-PD User Manual
Product codes
SY32K96H-PD
4 | Symmetra PX 96/160
5 | Symmetra PX 96/160
The high-density, efficient, scalable, modular UPS
Symmetra PX 96/160 features, continued
Energy efficiency
Independently verified by TÜV, the Symmetra PX
96/160 is 95% efficient to 35% loading, saving power
and cooling costs and significantly reducing your
overall total cost of ownership
96/160 is 95% efficient to 35% loading, saving power
and cooling costs and significantly reducing your
overall total cost of ownership
Load (%)
Curve fit to measured efficiency data. All measurements taken in
normal operating mode, at typical environmental conditions, with
nominal electrical input and balanced resistive load (PF = 1.0) output
Energy use/efficiency
APC Symmetra PX 160 kW 400 V, SY160K160H-PD
Efficiency (%)
0
10
20
30
40
50
60
70
80
90 100
100
90
80
70
60
50
Scalability and modularity
Scalable from 16 kW to 160 kW
• Modular components simplify future expansion
as your load grows
• N+1 redundant up to 144 kW
• Optional modular power distribution
• Hot swappable power and battery modules
• Hot-swappable breaker modules for UPS units
with power distribution
• All components conform to NetShelter SX
form-factor (H x W x D: 78.7 x 23.6 x 42.1 in,
1991 x 600 x 1070 mm)
1991 x 600 x 1070 mm)
• One-time installation service
Note: To expand the system from 96 kW to
160 kW, the input power cabling must be sized
for a Symmetra PX 160 kW at initial installation
160 kW, the input power cabling must be sized
for a Symmetra PX 160 kW at initial installation
Symmetra PX 96
1 power frame
1 battery frame
Up to 6 power modules
Up to 9 battery modules
1 battery frame
Up to 6 power modules
Up to 9 battery modules
Sample configurations
Symmetra PX 96 with
power distribution
power distribution
1 power frame
1 integrated power
1 integrated power
distribution, battery,
and MBP frame
Up to 6 power modules
Up to 9 battery modules
Up to 6 power modules
Up to 9 battery modules
Symmetra PX 160
1 power frame
2 battery frames
Up to 10 power modules
Up to 15 battery modules
2 battery frames
Up to 10 power modules
Up to 15 battery modules
Symmetra PX 160 with
power distribution
power distribution
1 power frame
1 battery frame
1 integrated power
1 battery frame
1 integrated power
distribution, battery,
and MBP frame
Up to 10 power modules
Up to 15 battery modules
Up to 10 power modules
Up to 15 battery modules
7
Network management card
Provides UPS status and event notification.
SmartSlot positions support dry contact,
environmental monitor, building management
system (Modbus
SmartSlot positions support dry contact,
environmental monitor, building management
system (Modbus
™
/Jbus), and additional
network management cards
8
Built-in static bypass switch
The hot-swappable static bypass switch
transfers the load to utility power without
interruption in case of heavy overload or
faulty conditions, and ensures that even in
125% overload conditions, the data center
remains operational
transfers the load to utility power without
interruption in case of heavy overload or
faulty conditions, and ensures that even in
125% overload conditions, the data center
remains operational
9
High-density footprint
Protect power and provide runtime in a mere
1.28 square meters for the Symmetra PX 96
kW or 1.92 square meters for the Symmetra
PX 160 kW. Integrate modular power
distribution and maintenance bypass without
changing the footprint, freeing valuable data
center space for IT equipment
1.28 square meters for the Symmetra PX 96
kW or 1.92 square meters for the Symmetra
PX 160 kW. Integrate modular power
distribution and maintenance bypass without
changing the footprint, freeing valuable data
center space for IT equipment
10
Modular power distribution (optional)
Adapt the modular power distribution solution
to meet changing demand—without a forced
shutdown. Monitor breaker positions and
simplify power management with output
metering and branch current/circuit monitoring
to meet changing demand—without a forced
shutdown. Monitor breaker positions and
simplify power management with output
metering and branch current/circuit monitoring
8
9
10
7