3
4-to-1 CombininG For PSm trAnSmitterS
Using the supplied BNC-BNC cables, connect the Antenna Output
1.
of each transmitter to the Antenna Inputs of the PA421SWB
(See Figure 2).
Attach an antenna to the MAIN Out of PA421SWB. For wideband
2.
applications, use PA805SWB directional antenna (Figure 1).
Connect the PA421SWB to a power outlet using one of the supplied
3.
power cables. The PA421SWB contains a universal power supply to
operate anywhere in the world.
If you have a Shure PSM system that has the same power input
4.
connectors as the PA421SWB power ouputs, such as the PSM400,
connect the PSM system to the PA421SWB via the supplied power
cables (see figure 2). This replaces the need for an external power
supply.
NOTE: The PA421SWB supplied power is 15 V and up to 660 mA.
®
PA80 5WB
Figure 2
NOTE: When the PA421SWB is powered on, the input signal
indicators (1-4) on the front panel will illuminate if an active
transmitter is connected to the corresponding input (1-4) on the
back panel (Figure 2).
LiCenSinG
Changes or modifications not expressly approved by Shure Incor-
porated could void your authority to operate the equipment. Licens-
ing of Shure wireless microphone equipment is the user’s respon-
sibility, and licensability depends on the user’s classification and
application, and on the selected frequency. Shure strongly urges the
user to contact the appropriate telecommunications authority concern-
ing proper licensing, and before choosing and ordering frequencies.
THIS RADIO EQUIPMENT IS INTENDED FOR USE IN PROFESSIONAL
ENTERTAINMENT AND SIMILAR APPLICATIONS.
NOTE: THIS EQUIPMENT MAY BE CAPABLE OF OPERATING ON
THIS RADIO EQUIPMENT IS INTENDED FOR USE IN PROFESSIONAL
ENTERTAINMENT AND SIMILAR APPLICATIONS.
NOTE: THIS EQUIPMENT MAY BE CAPABLE OF OPERATING ON
SOME FREQUENCIES NOT AUTHORIZED IN YOUR REGION. PLEASE
CONTACT YOUR NATIONAL AUTHORITY TO OBTAIN INFORMATION
ON AUTHORIZED FREQUENCIES FOR WIRELESS MICROPHONE
PRODUCTS IN YOUR REGION
Licensing: Note that a ministerial license to operate this equipment may
Licensing: Note that a ministerial license to operate this equipment may
be required in certain areas. Consult your national authority for possible
requirements.
OPERATION OF THIS DEVICE IS SUBJECT TO THE FOLLOWING TWO
CONDITIONS:
(1) THIS DEVICE MAY NOT CAUSE INTERFERENCE, AND
(2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE, INCLUDING INTER-
(1) THIS DEVICE MAY NOT CAUSE INTERFERENCE, AND
(2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE, INCLUDING INTER-
FERENCE THAT MAY CAUSE UNDESIRED OPERATION OF THE DEVICE.
SPeCiFiCAtionS
rF Carrier Frequency range
470-952 MHz
System Gain
+0/-5 dB
input AC Line Voltage
100-240 Vac, 50/60 Hz
maximum input Line VA
100 VA
maximum Current Drain
0.42-1.0 Amperes
(Amperes = 100 VA/Input AC Line Voltage)
maximum rF input Power
24 dBm (250 mW) per channel
input Signal indicator
threshold
+4 dBm (2.5 mW), +2 dBm (1.6 mW) typical
impedance
50 W nominal
operating temperature range
0× F (-18 × C) to +135× F (+57 × C)
overall Dimensions
43.4 mm high x 398.8 mm wide x331.5 mm
deep (1 11/16 in. H x 15 11/16 in. W x 13
1/2 in. D)
net Weight
4.53 Kg
(10 lbs unpackaged, without power and RF
cables)
input/output Connector type
BNC-type 4 input, 1 output ACTIVE
Power output
15 VDC, 660 mA each
NOTE: Electrical safety approval is based on a maximum
ambient temperature of 35°C.
FUrniSHeD ACCeSSorieS
(4) 2 ft. Coaxial Cable (rG58C/U)
UA802
(4) 2 ft. output Power Cable
95B8420
120 VAC Power Line Cord
95A8389
230 VAC Power Line Cord
95A8247
240 VAC Power Line Cord (U.K.)
95A8713
PA421SWb Frequency range
470-1100 MHz
Wideband Unidirectional Antenna
(470-952 mHz)
PA805SWB
10 ft. Coaxial Cable (rG-8X/U)
PA725
25 ft. Coaxial Cable (rG-8X/U)
UA825
50 ft. Coaxial Cable (rG-8X/U)
UA850
Wide band omnidirectional Antenna
UA860SWB
Helical Antenna
HA-8089 (480-900 MHz)
HA-8241(944-952 MHz)
oPtionAL ACCeSSorieS
CertiFiCAtionS
PA421SWB: Certified to FCC Part 74 (FCC ID No. DD4PA421SWB).
Certified in Canada by IC to RSS-123 AND RSS-102 (Certification No.
IC 616A-PA421SWB). UL LISTED to UL60065, 7th Edition and cUL
LISTED to CAN/CSA E60065-00. Meets the Essential Requirements
of the European R&TTE Directive 99/5/EC, eligible to bear CE mark.
Meets EMC requirements of EN 301 489 Parts 1 and 9 and is GS-
Certified to EN EN60065, 7th Edition. Conforms to Australian EMC
requirements, eleigible to bear C-Tick mark (N108)
N108
.