UTStarcom MSG2000 User Manual
Page 12-268
User Manual
Continuous Computing Corporation
Continuous Computing Corporation
FlexPacket ATCA PP50 Packet Processor
Preliminary
3.
Run command “ux_diag –d cn” to dump test result
4.
Run command “ux_diag –n cn” to list all related test result code description.
root@cnode-pp50:/ ux_diag -d cn
IPMC Diagnostic Test Result
===============================================================================
[MASK_POS] [TEST_TYPE] [TEST_CASE] [TEST_RESULT] [ERROR_CODE] [ERROR_STRING]
0 short post i2c passed 0 test passed
1 short post shortmem passed 0 test passed
Begin to generate cn_diag.dump.
Generate cn_diag.dump OK!
root@cnode-pp50:/
Note:
If some test items fail, you can get more details from the log file /
var/log/diag/cn_diag.dump.
root@cnode-pp50:/ ux_diag -n cn
IPMC Diagnosis Error Codes List
==============================
[code] [description]
0 test passed
1 not test
2 invalid test item
3 not response from i2c address
4 date line test error
5 address line test error
6 verify 0x00000000 error
7 verify 0xffffffff error
8 verify 0x55555555 error
9 verify 0xaaaaaaaa error
10 verify 1 shift error
11 verify address self error
12 verify address reverse error
13 verify address peak poke error
14 verify address bit fade error
15 a new second timeout
16 invalid second duration counts
17 month boundary test error
18 read old data error
19 erase old data error
20 write test data error
21 read test data error
22 verify test data error
23 erase test data error
24 restore old data error