UTStarcom MSG2000 User Manual

Page of 278
Page 2-54
User Manual
Continuous Computing Corporation
FlexPacket ATCA PP50 Packet Processor 
   
Preliminary
It is important to note that the fabric switch manager is part of the payload power 
domain. Therefore, the fabric switch and XLRs only start after the CNODE signals 
the fabric switch manager to power on. 
The CNODE signals the fabric switch manager to power on through a daemon, 
which runs a script that configures the fabric switch when the payload domain is 
activated. The daemon also monitors the fabric switch for proper functioning. For 
example, if a link is disconnected and reconnected, the switch responds appropri-
ately and the link continues to work uninterrupted. 
Figure 2-17: Power Domains, Startup
The fabric switch may also be custom configured to do things such as change traffic 
flow, handle VLANs, and direct certain packets to specific boards or payloads. A 
detailed description of fabric switch configuration is provided later in this 
document.