Port Commands
Table 36  Port Commands
Command
Description
SH PORT
Shows port parameters
Sample output:
Port     Q-Size     Type      Attributes
*S1        0       serial     115200 N 8 1 XON/XOFF 
CLEAR PORT S1 JOB
Aborts the active job on the port.  
If the remote host is connected, additional data received will be discarded. 
Format:
CL PORT S1 JOB
SET PORT S1 FLOW
Sets serial port flow control to NONE, XON/XOFF, CTS, or DSR
The default value is none.
Format:
SET PORT S1 FLOW <flow>
SET PORT S1 
PARITY
Sets serial port parity to NONE, EVEN, ODD, MARK, or SPACE
The default value is none.
Format:
SET PORT S1 Parity <parity>
SET PORT S1 SIZE
Sets data bits on the serial port
The default value is 8.
Format:
SET PORT S1 SIZE [7 | 8]
SET PORT S1 Speed
Sets serial port baud rate. Options for BAUD are 300, 600, 1200, 2400, 7200, 9600, 
19200, 38400, 57600, 115200, 230400, 460800, 921600
The default value is 115200.
Format:
SET PORT S1 SPEED <baudrate>
SET PORT S1 STOP
Sets serial port stop bits per character
The default value is 1.
Format:
SET PORT S1 STOP [1 | 2]