TP-LINK TL-SG5428 User Manual

Page of 216
 
199
 
 
Command Mode 
Global Configuration Mode 
Example 
Specify Hold Multiplier as 5: 
TP-LINK(config)# lldp hold-multiplier 5 
lldp timer 
Description 
The  lldp timer command is used to configure the parameters about 
transmission. To return to the default configuration, please use no lldp timer 
command. 
Syntax 
lldp timer tx-interval tx-interval 
lldp timer tx-delay tx-delay 
lldp timer reinit-delay reinit-delay 
lldp timer notify-interval notify-interval 
lldp timer fast-count fast-count 
no lldp timer tx-interval 
no lldp timer tx-delay 
no lldp timer reinit-delay 
no lldp timer notify-interval 
no lldp timer fast-count 
Parameter 
tx-interval —— Configure the interval for the local device to transmit LLDPDU to 
its neighbors. By default, it is 30 seconds. 
tx-delay —— Configure a value from 1 to 8192 in seconds to specify the time for 
the local device to transmit LLDPDU to its neighbors after changes occur so as 
to prevent LLDPDU being sent frequently. By default, it is 2 seconds. 
reinit-delay ——This parameter indicates the amount of delay from when LLDP 
status becomes "disable" until re-initialization will be attempted. The default 
value is 3. 
notify-interval —— Specify the interval of Trap message which will be sent from 
local device to network management system. By default, it is 5 seconds. 
fast-count ——When the port's LLDP state transforms from Disable (or
 
Rx_Only)