This mount unit for most makes of Plasma displays provides flat to wall mounting or tilting to
10 degrees as required. The unit can also be fitted to UNICOL Plasma Mount Sockets for mounting
on Trolleys/Stands or from ceilings.
The unit is designed for easy installation and comes in two parts, Plasma Plate and Back Plate.
Preparation
Detach the two parts of the PLW by locating the 4 M10 x 25
hex head screws located at either end of the unit. Remove
the bottom 2 screws completely, identified by the elongated
hole in the Plasma Plate. Loosen the top 2 screws
sufficiently in order to be able to detach the two parts.
Wall Fixing
Using the 10mm dia holes located in the Back Plate, 
screw the plate to a suitable wall or other load bearing
vertical surface.  Care should be taken to ensure that
the Back Plate is installed level.
Secure installation of this unit is vital, fixing should
normally be into walls of brick, masonry or concrete
using expanding bolts or other reliable fastenings.
Consult your builder or architect if in doubt.
Fixing to Plasma Mount Sockets
Align the Back Plate holes, at 150mm centres, with the
Plasma Mount Socket and fix using the 4 x M10 x 25 
Hex Head screws supplied.
Attaching the Plasma Plate
  
Installing the Plasma display into the
Back Plate
The installing technician and an assistant should carefully
lift the Plasma display unit with its Plasma Plate attached,
onto the 2 M10 x 25 screws remaing at either end of the
Back Plate. Refit the 2 bottom screws and tighten to the
desired tilt angle, tighten 2 top screws to complete the
installation.
Parts List:
Qty 1 x Plasma Plate
Qty 1 x Back Plate
Qty 4 x M10 x 25 Hex Head Screws
Plasma Fixing screws (relevant to Plasma display)
(Qty 4 x M10 x 25 Hex Head Screws when ordered for 
Plasma Mount Socket use)
UPLW702GEN
Back
Plate
Plasma 
Plate
PLW Assembled
Shown for
Flat to Wall 
Mounting
Patent Pending, Registered Design
PLASMA DISPLAY TILTING WALL MOUNT - A
M10 x 25  
Hex Head screws
Typical Mount Shown
Remove any existing mounting screws from the Plasma display fixing 
points ensuring that any plastic bushes fitted with the Plasma remain
in situ. Discard existing screws. (if fitted)
Align the Plasma Plate with the fixing points on the back of the 
Plasma display. Arrow shaped holes indicate the correct way up.
Fully tighten the fixing screws supplied to complete this operation. 
 
See overleaf for