Toshiba IK-TF5U User Manual

Page of 36
28
( 4 )   PW SR (Pulse width trigger SYNC-RESET)
The trigger input to the CC1 of the DIGITAL terminal develops 1 frame images.
(4. 1) 1 Pulse Width Trigger SYNC-RESET Picture Output Timing
*1: Externally input signal
*2: Exposure time = Trigger pulse width + 6 
µ
s
(Valid trigger pulse width is 2 
µ
s or greater for external trigger shutter operation.)
*3: VD is generated after 0 to 1H following the completion of the exposure period and the video is synchro-
nized to this and output.
Note:
When the next trigger is input before completion of the output of the video corresponding to the trig-
ger, there will be an effect on the video.
About 1 
µ
s
About 7 
µ
s
Exposure completion
0 to 1H
Trigger*
1
Negative polarity mode
Positive polarity mode
Exposure period*
2
(Internal VD)*
3
RGB data 
(video interval image)
FVAL
LVAL, 
DVAL
20H (Partial scanning OFF)
14H (Partial scanning 90fps)
18H (Partial scanning 115fps)
18H (Partial scanning 120fps)
22H (Partial scanning 160fps)
23H (Partial scanning 180fps)
26H (Partial scanning 240fps)