184
 
f-hold
  ——  The falling counter value that triggers the Falling Threshold alarm, 
ranging from 1 to 65535. By default, it is 100. 
f-event
  —— Fall Event, which is the index of the corresponding event which 
will be triggered if the sampled value is lower than the Falling Threshold. It 
ranges from 1 to 12. 
a-type  ——  Alarm Type, with rise, fall and all options. Rise indicates that the 
alarm event will be triggered when the sampled value exceeds the Rising 
Threshold, fall indicates that the alarm event will be triggered when the sampled 
value is under the Falling Threshold, and all indicates that the alarm event will 
be triggered either the sampled value exceeds the Rising Threshold or is under 
the Fall Hold. By default, the Alarm Type is all. 
interval
  ——  The alarm interval time, ranging from 10 to 3600 in seconds. By 
default, it is 1800. 
Command Mode 
Global Configuration Mode 
Example 
Configure the alarm interval time of the entries 1,2,3 and 6 as 1000 seconds: 
TP-LINK(config)# snmp-rmon alarm config 
1-3,6 interval 1000 
snmp-rmon alarm owner 
Description 
The snmp-rmon alarm owner command is used to configure the owner of the 
Alarm Management entry. To return to the default configuration, please use no 
snmp-rmon alarm owner
 command. 
Syntax 
snmp-rmon alarm owner 
{index} [owner
no snmp-rmon alarm owner 
{index} 
Parameter 
index
  ——  The index number of the entry, ranging from 1 to 12. You can only 
select one entry for each command. 
owner
  ——  The owner of the entry, ranging from 1 to 16 characters. By default, 
it is monitor. 
Command Mode 
Global Configuration Mode 