80 Device Programming Menu Mode 
 
STOP 
The "STOP" programming determines when and under what conditions the device will be de-
activated. The following options are available: 
 
Upon Restore of a Zone List 
Restore Zone List: If a "ZONE LIST" is used as the “Stop” event, the device will de-activate when all the 
zones in that list restore from a previous fault, trouble, or alarm condition.  This will occur regardless of 
what is programmed to "START" the device; therefore, a "RESTORE ZONE LIST" would normally only be 
used when a "ZONE LIST" is used to start the device. 
 
Upon a Zone Type or System Operation 
Zone Type/System Operation: Instead of using a "RESTORE ZONE LIST," a specific zone (response) type or 
system operation action can be selected to de-activate the device. 
•  If a specific "ZONE TYPE" is chosen, any zone of that response type that restores from a previous alarm, 
trouble, or fault condition will cause the device to de-activate. 
•  If a "SYSTEM OPERATION" is chosen, that operation will cause the device to de-activate.   
During normal system operation, any devices may be manually started by keypad entry of: Code* + [#] 
+ 4 + “n;” 
or manually stopped by keypad entry of: Code* + [#] + 7 + “n,” where “n” = the device number to 
be controlled. 
* Code is required for devices 7 and 8. For devices 1-6, code is not required. See User Manual for more 
information. 
 
Programming Powerline Carrier Devices 
 
While in program mode, press 
80 to enter Output Device Menu Mode. This mode is used to program 
all output devices used in the system. Refer to the output device table for 
80 on the separate programming 
form when programming output devices. 
 
Note: The House ID of the Powerline Carrier Devices must be entered in data field 
25. 
 
The prompts for 
80 are as follows: 
 
          80 
Powerline Carrier Device Programming Main Menu prompt 
 
A  01 
Device Number--------------------- for entering the device number 
 
b  
Device Action ----------------------- for defining the action the device will perform when active 
 
Start Event Type ------------------ for assigning the event type to start the action 
 
Start Zone List --------------------- for assigning the zone list to start the action 
 
Start Zone Type-------------------- for assigning the zone type to start the action 
 
Stop Zone List ---------------------- for assigning the zone list to stop the action 
 
1A 
Stop Zone Type--------------------- for assigning the zone type to stop the action 
 