Smeg PTS723-3 User Manual

Page of 16
 
 
 
Instructions for the Installer 
 
 
12 
5.5 
Adjusting the primary air flow 
Refers to the gap “X” in mm. 
 
BURNER 
 
G30/G31 
30/37 mbar 
 
G110 
8 mbar 
 
G20 
20 mbar 
Semi rapid (1) 
10.0 
1.5 
2.0 
Rapid (2) 
8.0 
1.5 
2.5 
 
Ultra-Rapid (3) 
12.0 
5.0 
2.5 
To identify the burners on your hob, refer to the drawings in point “5.8 Hob burner 
layout” 
 
5.6 
Reassembling the hob skin 
Reverse the procedure described in point “5.1 Removing the hob skin ”. 
 
 
 
 
When replacing the burner rings, bear in mind that they must be
 fully tightened using 
the spanner provided. 
 
 
Put the pan stands back in place, fitting first those at the side and then the central one.
 
5.7 
Adjusting the minimum setting for natural gas and town gas 
Reassemble the components on the burner and fit the 
knobs onto the tap rods. 
Light the burner and turn it to the minimum   setting . 
Remove the knob again and adjust the regulator 
screw inside or beside the tap rod (depending on the 
model) until an even minimum flame is obtained. 
Put the knob back in place and check the stability of 
the burner flame (the flame must not go out when the 
knob is turned quickly from the maximum to the 
minimum setting).  
 
5.8 
Adjusting the minimum for bottled gas 
To adjust the minimum level when using bottled gas, the adjuster screw inside or 
beside the tap rod must be turned fully clockwise (depending on the models). 
The diameters of the bypasses for each individual burner are stated in point “5.2 
Adjusting for bottled gas". 
 
 
 
 
After adjusting for use of a gas other than the gas used for testing the appliance, 
replace the label on the casing with the label for the new gas. The label is supplied in 
the bag with the LPG nozzles (G30 ˆ G31).