Travelstar E7K100 (SATA) Hard Disk Drive Specification
96 
12.9  Idle (E3h/97h)
Table 61: Idle command (E3h/97h)
When the power save mode is Standby mode, the Idle command causes the device to enter Performance Idle mode 
immediately and sets the auto power down time-out Parameter (standby timer). At the set of the auto power down 
time-out parameter (standby timer) the point timer starts counting down. When the power save mode is already any 
idle mode, the device remains in that mode. 
When the Idle mode is entered, the device is spun up to operating speed. If the device is already spinning, the spin 
up sequence is not executed.
During Idle mode the device is spinning and is ready to respond to host commands immediately.
Input parameters to the device
Sector Count 
This indicates the Time-out Parameter. If it is zero, the time-out interval (Standby Timer) 
is disabled. If it is other than zero, the time-out interval is set for (Time-out Parameter × 5) 
seconds.
The device will enter Standby mode automatically if the time-out interval expires with no 
device access from the host. The time-out interval will be reinitialized if there is a device 
access before the time-out interval expires.
   
Command Block Output Registers
Command Block Input Registers
Register
7 6 5 4 3 2 1 0
Register
7 6 5 4 3 2 1 0
Data
- - - - - - - -
Data
- - - - - - - -
Feature
- - - - - - - -
Error
see below
Sector Count
V V V V V V V V
Sector Count
- - - - - - - -
LBA Low
- - - - - - - -
LBA Low
- - - - - - - -
LBA Mid
- - - - - - - -
LBA Mid
- - - - - - - -
LBA High
- - - - - - - -
LBA High
- - - - - - - -
Device
- - - - - - - -
Device
- - - - - - - - 
Command
1 1 1 0 0 0 1 1
Status
see below
Error Register
Status Register
7
6
5
4
3
2
1
0
7
6
5
4
3
2
1
0
CRC
UNC
0
IDN
0
ABT
T0N
AMN
BSY RDY
DF
DSC
DRQ
COR IDX
ERR
0
0
0
0
0
V
0
0
0
V
0
V
-
0
-
V