Travelstar E7K100 (SATA) Hard Disk Drive Specification
106 
12.16  Read Log Ext (2Fh)
Table 67: Read Log Ext Command (2Fh)
This command returns the specified log to the host. The device shall interrupt for each DRQ block transferred.
Output parameters to the device
Sector Count Current
The number of sectors to be read from the specified log low order, bits (7:0). The 
log transferred by the drive shall start at the sector in the specified log at the spec-
ified offset, regardless of the sector count requested.  
Sector Number Previous
The number of sectors to be read from the specified log high orders, bits (15:8).
Sector Number Current
The log to be returned as described in the figure below.
Cylinder Low Current
The first sector of the log to be read low order, bits (7:0).
Cylinder Low Previous
The first sector of the log to be read high order, bits (15:8).
Command Block Output Registers
Command Block Input Registers
Register
7 6 5 4 3 2 1 0
Register
7 6 5 4 3 2 1 0
Data Low
- - - - - - - -
Data Low
- - - - - - - -
Data High
- - - - - - - -
Data High
- - - - - - - -
Feature
Current
- - - - - - - -
Error see 
below
Previous
- - - - - - - -
Sector 
Count
Current
V V V V V V V V
Sector 
Count
HOB=0
- - - - - - - -
Previous
V V V V V V V V 
HOB=1
- - - - - - - -
Sector 
Number
Current
V V V V V V V V
Sector 
Number
HOB=0
- - - - - - - -
Previous
- - - - - - - -
HOB=1
- - - - - - - -
Cylinder 
Low
Current
V V V V V V V V
Cylinder 
Low
HOB=0
- - - - - - - -
Previous
V V V V V V V V
HOB=1
- - - - - - - -
Cylinder
High
Current
- - - - - - - -
Cylinder
High
HOB=0
- - - - - - - -
Previous
- - - - - - - -
HOB=1
- - - - - - - -
Device/Head
- - - - - - - -
Device/Head
- - - - - - - -
Command
0 0 1 0 1 1 1 1
Status
See below ...
Error Register
Status Register
7
6
5
4
3
2
1
0
7
6
5
4
3
2
1
0
CRC
UNC
0
IDN
0
ABT
T0N
AMN
BSY RDY
DF
DSC
DRQ
COR IDX
ERR
V
V
0
V
0
V
0
0
0
V
0
V
-
0
-
V