Fujitsu MAT3300FC User Manual

Page of 460
Command Specifications 
 
4-198 
C141-C008 
This command reads the logical data block data and its ECC byte, specified in the 
“Logical block address” field in the CDB, from the disk media and transfers it to 
the INIT.  Normally, this command is used in combination with the WRITE 
LONG command to perform checks of the ECC function.  The operation object in 
this command is 1 data block only. 
Remark  The Pad Byte and Sync Byte patterns are not included in the transfer 
data. 
When “0” is specified in bit 1 of CDB byte 1, the “CORRCT (Corrected)” bit, the 
IDD does not implement ECC correction processing of data read from the disk 
media.  When “1” is specified in the “CORRCT (Corrected)” bit, data errors that 
can be corrected by ECC are transferred to the INIT after being corrected in the 
IDD’s data buffer. 
When the “Transfer byte length” specifies zero, this command executes a seek 
operation of the cylinder/track existing in the logical data block which is specified 
in the “Logical block address” field in the CDB., then is terminated without data 
being transferred to the INIT. 
When a length (other than zero) which does not match the data format on the disk 
media is specified in the “Transfer byte length” field in the CDB, this command is 
terminated with a CHECK CONDITION status without executing a data transfer 
to the INIT.  At this time, the sense data indicate the following contents and the 
INIT can determine the correct “Transfer byte length” from their contents. 
•  Sense Key 
:  05 = ILLEGAL REQUEST 
•  Sense Code/Sub-sense Code  :  24-00 = Invalid field in CDB 
• “VALID” 
Bit 
“1” 
• “ILI” 
bit 
“1” 
•  Information Field: (“Transfer byte length in the CDB) –  
(Original “Transfer byte length”) 
Remark:  The calculation formula for the information field expresses 1 logical 
data block as n physical sectors, and when negative, as a complement  
of 2. 
Error recovery processing during execution of this command is in accordance 
with the specifications in (Page code 1:  Read/Write Error Recovery Parameter, 
Page code 21:  Additional error recovery parameters). 
•  The ARRE flag and the DTE flag are not applied. 
•  The TB flag is treated as if “1” was specified.