Hitachi RAK-35PPA RAK35PPA User Manual
Product codes
RAK35PPA
GENERAL DATA
2-30
2.2.20.
DUCT TYPE (RAC-50DPA/60DPA/70DPA)
OUTDOOR
UNIT
RAC-50DPA
RAC-60DPA
RAC-70DPA
Minimum / Maximum indoor units
connectable
connectable
-
-
-
Minimum / Maximum connected
capacity
capacity
-
-
-
Nominal Cooling capacity (min - max)
kW
5.0 (0.9-6.0)
6.0 (0.9-7.0)
7.1 (0.9-8.0)
Nominal Heating capacity (min - max)
kW
6.0 (0.9-7.0)
7.3 (0.9-8.0)
8.0 (0.9-9.0)
Nominal cooling power input (min -
max)
max)
kW
1.4 (0.200-2.500)
1.87 (0.200-2.500)
2.53 (0.200-2.920)
Nominal heating power input (min -
max)
max)
kW
1.59 (0.200-2.200)
2.13 (0.200-2.600)
2.34 (0.200-3.100)
EER / COP
3.57/3.77
3.21/3.43
2.81/3.42
SEER / SCOP
5.4/3.8
5.1/3.8
5.1/3.8
Energy class (SEER/SCOP)
A/A
A/A
A/A
Noise level cooling (sound pressure)
dB(A)
47
48
53
Noise level heating (sound pressure)
dB(A)
50
51
55
Noise level (sound power)
dB(A)
65
65
67
Air flow (Cooling / Heating)
m
3
/h
-/-
-/-
-/-
Static pressure (nominal conditions,
maximum)
maximum)
Pa
-
-
-
Dimensions (H x W x D)
mm
800x850x298
800x850x298
800x850x298
Weight
kg
51.5
55.0
55.0
Colour (Munsell Code)
Beige (5Y 7/2)
Power supply
220-230V , 1Ph , 50Hz
220-230V , 1Ph , 50Hz
220-240V , 1Ph , 50Hz
Recommended fuse size
A
30
30
30
Starting current
A
10.0
10.0
10.0
Running current
A
6.40-5.90/7.30-6.70
8.55-7.90/9.75-9.00
11.60-10.70/10.70-9.80
Cable section
mm
2
2.000
2.000
2.000
Interconnection between indoor unit
and outdoor unit
and outdoor unit
mm
2
2x2.5 + 2x1.6 or 2.0
2x2.5 + 2x1.6 or 2.0
2x2.5 + 2x1.6 or 2.0
Piping diameter (Liq / Gas)
1/4" / 1/2"
1/4" / 1/2"
1/4" / 5/8"
Minimum piping length
m
5.0
5.0
5.0
Maximum piping length / height
difference
difference
m
30 / 20
30 / 20
30 / 20
Current quantity of refrigerant /
Chargeless
Chargeless
kg
1.80
1.80
1.80
Chargeless / Additional refrigerant
charge
charge
m / g/m
30/-
30/-
30/-
Working range (cooling / heating)
°C
-10 ~ 43 / -15 ~ 21
-10 ~ 43 / -15 ~ 21
-10 ~ 43 / -15 ~ 21
Refrigerant
R410A
R410A
R410A
Condenser Fan
Propeller Fan
Compressor
Type
2 Cylinder Rotary
2 Cylinder Rotary
2 Cylinder Rotary
Oil Type
HAF68D1
HAF68D1
HAF68D1
Oil Charge
ml
480
480
580
Coil Resistance
ˈ
1.05 at 20
C
1.05 at 20
C
1.05 at 20
C
1.268 at 75
C
1.268 at 75
C
1.268 at 75
C
Quantity
1
1
1
NOTE:
1. The Sound Pressure Level is based on the following conditions:
-
1.5 meter from the unit front surface and 1.5 meter from floor level
The above data was measured in an anechoic chamber. Please take into consideration reflected sound of your specific
site
site