112 
3.  Secure the junction box (GV-Mount203, No. 1) to the mounting plates from the backside 
using the 25 mm M8 screw (GV-Mount300, No. 3), plain washer (GV-Mount300, No. 4), 
and split washer (GV-Mount300, No. 5).  
 
 
 
Back View 
4.  Secure the mounting plates to the wall with 8 self-prepared screws. Face the conduit exit 
downward. 
5.  Assemble the corrugated tube connector (GV-Mount203, No. 4) with the self-prepared 
corrugated tube. 
A.  Dismantle the supplied corrugated tube connector. You should have 4 parts. 
A B
C
D
 
B.  Slide part A and part B to the self-prepared corrugated tube. 
A+B
C
D
 
C.  Screw part C to the tube. 
D.  Thread the necessary wires and cables from the wall or the ceiling through the 
corrugated tube, plug the tube to the box and secure with part D. 
Ethernet
Power