Fujitsu RX300 S7 + Windows Small Business Server 2011 Standard VFY:R3007SF010NC+SBSSTD2011 Data Sheet

Product codes
VFY:R3007SF010NC+SBSSTD2011
Page of 10
Data Sheet
 Fujitsu PRIMERGY RX300 S7 Dual socket 2 U rack server 
Page 7 / 10
www.fujitsu.com/fts
Server Management
Server Management notes
Regarding Operating System dependencies for ServerView Suite software Products see dedicated Product Data sheets.
Dimensions / Weight
Rack (W x D x H)
482.6 mm (Bezel) / 445mm (Body) x 770 x 86.9 mm
Mounting Depth Rack
735 mm
Height Unit Rack
2 U
19” rackmount
Yes
Weight
up to 25 kg
Weight notes
Actual weight may vary depending on configuration
Rack integration kit
Rack integration kit as option
Environmental
Operating ambient temperature
10 - 35°C
Operating relative humidity
10 - 85 % (non condensing)
Operating environment
FTS 04230 – Guideline for Data Center (installation locations)
Operating environment Link
http://docs.ts.fujitsu.com/dl.aspx?id=d4ebd846-aa0c-478b-8f58-4cfbf3230473
Noise emission
Measured according to ISO 7779 and declared according to ISO 9296
Sound pressure (LpAm)
Low noise mode: 25 dB(A) min,  29 dB(A) max (idle) / 27 dB(A) min, 32 dB(A) max (operating)
Performance mode: 48 dB(A) (idle) / 48 dB(A) min, 68 dB(A) max (operating)
Sound power (LWAd; 1B = 10dB)
Low noise mode: 4.1 B min, 4.5 max (idle) / 4.1 B min, 4.9 B max (operating)
Performance mode: 6.5 B (idle) / 6.5 B min, 8.2 B max (operating)
Electrical values
Power supply configuration
1-2x 450W/800W hot-plug power supply
Max. output of single power supply
450/800 W  (94% efficiency)
Power supply efficiency
94% (at 50% PSU load, CSCI “platinum”)
Hot-plug power supply output
450/800 W  (94% efficiency)
Hot-plug power supply redundancy
Yes
Rated voltage range
100 V - 240 V
Rated frequency range
47 Hz - 63 Hz
Rated current max.
8.2 A (100 V) / 3.3 A (240 V) 
Rated current in basic configuration
100 V - 240 V /  TBD
Active power (min. configuration)
53 W
Active power (max. configuration)
830 W
Apparent power (max. configuration)
873 VA
Heat emission
2988.0 kJ/h (2832.1 BTU/h)
Power Supply Notes
Power Safeguard adapts system performance in case the wattage exceeds supply limits.
Compliance
Germany
GS
Europe
CE Class A *
USA/Canada
CSAc/us
FCC Class A
Global
CB
RoHS (Restriction of hazardous substances)
WEEE (Waste electrical and electronical equipment)
Japan
VCCI
China
CCC (planned)
CCC (depending on configuration)
Australia/New Zealand
C-Tick
Compliance notes
There is general compliance with the safety requirements of all European countries and North America. National 
approvals required in order to satisfy statutory regulations or for other reasons can be applied for on request.
* Warning:
This is a class A product. In a domestic environment this product may cause radio interference in which case the user 
may be required to take adequate measures.
Compliance link
http://sp.ts.fujitsu.com/sites/certificates/