Mass Configuration: Sensor and Alert Settings
128
InfraStruXure Central 4.1 User’s Reference
Configuring an E-mail Periodic Report
To configure devices to periodically generate and e-mail sensor reports to specified recipients:
1. Select a device group or container from the navigation pane, or select one or more devices from the 
device list pane.
2. Double-click on the Periodic Reports icon.
3. Select the E-Mail Periodic Report from the Periodic Reports drop box. Any selected devices with 
previously created report generation entries of this type are displayed.
4. Click Add, then select one or more NetBotz devices from the device selection list and click Next. 
5. A Periodic Report configuration interface window opens. This window contains the following 
fields:
Field
Description
Enabled
Check this check box to enable periodic e-mail reporting.
Include camera pictures
Check this check box to include current image captures by 
Camera Pod 120s connected to the NetBotz device in the e-
mailed report. Image captures that are included with periodic 
reports are 640x480 resolution, regardless of appliance Camera 
settings.
Include maps
Check this check box to include any maps that are stored on the 
appliance in the e-mailed report.
Include graphs
Check this check box to include graphs of the sensor readings 
for all sensors that are associated with the appliance in the e-
mailed report.
Interval
The frequency with which e-mail reports will be generated.
Sensor priority
Acts as a filter that can be used to limit the amount of sensor 
data that is included with the periodic report.  You can select 
High, Medium, or Low priority settings:
• High: Only sensor data associated with physical sensors that 
are integrated with or connected to the appliance are included 
in the report.  Sensor data associated with remote devices, 
such as MIB II data gathered from remote targets using Basic 
Device Crawlers and Advanced Data that is gathered using 
add-on applications such as Advanced Device Crawlers, is not 
included in the report.
• Medium: Sensor data associated with physical sensors and 
with Advanced Data sensor sets from remote devices (such as 
that which is gathered using Advanced Device Crawlers) is 
included in the report.  Data associated with remote devices 
that is not grouped in an Advanced Data sensor set, such as 
MIB II data gathered from remote targets using Basic Device 
Crawlers, is not included in the report.
• Low: Sensor data from all sensors is included in the report.