Finder 7S.12.9.024.5110 - 6A Relay Module With Forcible Guided Contacts SPST-NO, SPST-NC 250Vac IP20 7S.12.9.024.5110 Data Sheet

Product codes
7S.12.9.024.5110
Page of 6
7S.12.....5110
7S.14.....0220/0310
7S.16…..0420
Relay module with forcibly guided contacts
7S.12 with 2 pole (1NO + 1 NC) 
7S.14 with 4 pole (2 NO + 2 NC and 
3 NO + 1 NC)
7S.16 with 6 pole (4 NO + 2 NC)
For safety applications, with class A forcibly 
guided contact relays (EN 50205)
For functional reliability in machinery and 
plant engineering according to EN 13849-1
For railway applications; materials compliant 
with fire and smoke characteristics 
(UNI 11170-3); mechanical and climatic 
characteristics compliant with EN 61373 and 
EN 50155
DC and AC supply versions
24 and 110 V DC versions with extended 
operating range (0.7....1.25) U
N
Coil status visual indication with LED
35 mm rail (EN 60715) mount
1 NO + 1 NC
2 NO + 2 NC, 3 NO + 1 NC
4 NO + 2 NC
6/15
6*/12
6*/12
250
250
250
1,500
1,500
1,500
700
500
500
6/0.6/0.2
6/0.6/0.3
6/0.6/0.3
1
1
1
60 (5/5)
60 (5/5)
60 (5/5)
AgNi + Au (5 μm)
AgNi with notched crown
AgNi with notched crown
110...125 - 230...240
110...125 - 230...240
110...125 - 230...240
12 - 24
12 - 24 - 110
12 - 24 - 110
2.3/1
2.3/1
2.3/1
(0.85...1.1) U
N
(0.85...1.1) U
N
(0.85...1.1) U
N
(0.8...1.2) U
N
(0.8...1.2) U
N
(0.8...1.2) U
N
(0.7....1.25) U
N
(0.7....1.25) U
N
(0.7....1.25) U
N
0.45 U
N
/0.45 U
N
0.55 U
N
/0.55 U
N
0.55 U
N
/0.55 U
N
0.1 U
N
/0.1 U
N
0.1 U
N
/0.1 U
N
0.1 U
N
/0.1 U
N
10 · 10
6
10 · 10
6
10 · 10
6
100 · 10
3
100 · 10
3
100 · 10
3
7/11
12/10
12/10
6
6 (4 against 13-14)
6 (4 against 13-14)
1,500
1,500
1,500
–40….+70
–40….+70
–40….+70
IP 20
IP 20
IP 20
1
2 pole (1 NO + 1 NC)
4 pole (2 NO + 2 NC
and 3 NO + 1 NC)
6 pole (4 NO + 2 NC)
Contact specification
Contact configuration
Rated current / Max. peak current
A
Rated switching voltage
V AC (50/60 Hz)
Rated load AC1
VA
Rated load AC15 (230 V AC)
VA
Breaking capacity DC1: 30/110/220 V
A
Breaking capacity DC13: 24 V
A
Minimum switching load
mW (V/mA)
Standard contact material
Coil specification
Nominal voltage (U
N
)
V AC (50/60 Hz)
V DC
Rated power
VA (50 Hz) / W
Operating range
AC
DC
DC extended range (24 and 110 V only)
Holding voltage
AC/DC
Must drop-out voltage
AC/DC
Technical data
Mechanical life
cycles
Electrical life at rated load AC1
cycles
Operate / release time
ms
Insulation between coil and contacts (1.2/50 μs) kV
Dielectric strength between open contacts V AC
Ambient temperature
°C
Protection category
Approvals (according to type)
Features
7S Series - Relay module with forcibly guided contacts 6 A
Screwless terminal
* Single contact current ≤ 6 A, 
total NO contacts current ≤ 12 A