Finder 4C.02.9.024.0050 8A Relay Interface Module 2 changeover contacts. 24 Vdc 4C.02.9.024.0050 Data Sheet

Product codes
4C.02.9.024.0050
Page of 6
4
4C Series - Relay interface modules 8 - 10 - 16 A
Contact specification
F 4C - Electrical life (AC) v contact current
Types 4C.01/51
(*) Type 4C.01= 12 A, Type 4C.51= 10 A
• When switching a resistive load (DC1) having voltage and current   
values under the curve, an electrical life of ≥ 100·10
3
can be expected.
• In the case of DC13 loads, the connection of a diode in parallel with
the load will permit a similar electrical life as for a DC1 load.
Note: the release time for the load will be increased.
H 4C - Maximum DC1 breaking capacity
DC breaking current (A)
DC voltage (V)
F 4C - Electrical life (AC) v contact current
Types 4C.02/52
Current limit 1 CO (SPDT) (*)
Current limit 2 CO (DPDT)
Nominal
Coil
Operating range
Resistance Rated coil
voltage
code
consumption
U
N
U
min
U
max
R
I at U
N
V
V
V
Ω
mA
12
9.012
8.8
13.2
300
40
24
9.024
17.5
26.4
1,200
20
125
9.125
91.2
138
32,000
3.9
DC coil data
Coil specifications
Nominal
Coil
Operating range
Resistance Rated coil
voltage
code
consumption
U
N
U
min
U
max
R
I at U
N
V
V
V
Ω
mA
12
8.012
9.6
13.2
80
90
24
8.024
19.2
26.4
320
45
110
8.110
88
121
6,900
9.4
120
8.120
96
132
9,000
8.4
230
8.230
184
253
28,000
5
AC coil data
- Max. permitted coil voltage.
- Min. pick-up voltage with coil at ambient temperature.
R 4C - DC coil operating range v ambient temperature
- Max. permitted coil voltage.
- Min. pick-up voltage with coil at ambient temperature.
R 4C - AC coil operating range v ambient temperature
Temperature limit for the single pole version under full 16 A contact current.
Single Pole Relay
Contact Current
limited to 12 A 
Single Pole Relay
Contact Current
limited to 12 A 
Cycles
Resistive load - cos
ϕ = 1
Inductive load - cos
ϕ = 0.4
Cycles
Resistive load - cos
ϕ = 1
Inductive load - cos
ϕ = 0.4
limit for 4C.51