Tele 170010 Relay 1 changeover contact 170010 Data Sheet
Product codes
170010
Coupling relays - OCTO series
HAR1
Installation design
Width 17.5mm
Three-way switch:
permanently OFF or ON, automatic
Checkback signal of the switch setting 'AUTO‘
1 change over contact
Width 17.5mm
Three-way switch:
permanently OFF or ON, automatic
Checkback signal of the switch setting 'AUTO‘
1 change over contact
4.02 – 1
7. Ambient conditions
Ambient temperature: -25 to +55°C (according to IEC 68-1)
Storage temperature: -25 to +70°C
Transport temperature: -25 to +70°C
Relative humidity: 15% to 85%
(according to IEC 721-3-3 class 3K3)
Pollution degree: 2, if built-in 3
(according to IEC 664-1)
8. Dimensions
1. Functions
AUTO
automatic
0
permanently OFF
HAND
permanently ON
2. Indicators
Yellow LED ON/OFF:
indication of relay output
3. Mechanical design
Self-extinguishing plastic housing, IP rating IP40
Mounted on DIN-Rail TS 35 according to EN 50022
Mounting position:
any
Shockproof terminal connection according to VBG 4
(PZ1 required), IP rating IP20
Initial torque:
max. 1Nm
Terminal capacity:
1 x 0.5 to 2.5mm² with/without multicore cable end
1 x 4mm² without multicore cable end
2 x 0.5 to 1.5mm² with/without multicore cable end
2 x 2.5mm² flexible without multicore cable end
4. Input circuit
Supply voltage:
24V AC/DC
terminals A1(+)-A2
Signal voltage:
24V AC/DC
terminals A3(+)-A2
Tolerance:
-15% to +10%
Rated frequency:
48 to 63Hz
Rated consumption:
0.5VA (0.5W)
Duration of operation: 100%
Reset time:
-
Residual ripple for DC: 10%
Drop-out voltage:
>10% of supply voltage
5. Output circuit
1 potential free change over contact
Switching capacity (distance < 5mm):
1250VA (5A / 250V AC)
Switching capacity (distance > 5mm):
2000VA (8A / 250V AC)
Fusing:
8A fast acting
Mechanical life:
20 x 10
6
operations
Electrical life:
2 x 10
5
operations
at 1000VA resistive load
Switching frequency: max. 60/min at 100VA resistive load
max. 6/min at 1000VA resistive load
(according to IEC 947-5-1)
Insulation voltage:
250V AC (according to IEC 664-1)
Surge voltage:
4kV, overvoltage category III
(according to IEC 664-1)
6. Check-back
Position 'AUTO‘:
terminals B1-B2
Maximal switching capacity:
24VA (500mA / 48V AC/DC)
Minimal switching capacity:
5mVA (1mA / 5V AC/DC)
Contact resistance:
max. 20mΩ
Electrical life:
3 x 10
4
operations
at maximum load
Technical data
Subject to alterations and errors
Release 11/01