MEAN WELL LED driverLED-switching power supply LCM-60 LCM-60 Data Sheet

Product codes
LCM-60
Page of 5
SPECIFICATION
MODEL
LCM-60
DC VOLTAGE RANGE
RATED POWER               
OUTPUT
SETUP, RISE TIME          
Note.5
HOLD UP TIME (Typ.)
VOLTAGE RANGE          
Note.4
FREQUENCY RANGE
POWER FACTOR (Typ.)
TOTAL HARMONIC DISTORTION
EFFICIENCY (Typ.)         
Note.6
AC CURRENT (Typ.)
INPUT
INRUSH CURRENT(Typ.)
LEAKAGE CURRENT
SAFETY STANDARDS
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSION
OTHERS
NOTE
PACKING
2 ~ 90V
2 ~ 86V
2 ~ 90V
2 ~ 67V
2 ~ 57V
2 ~ 42V
60.3W
±5%
700mVp-p
95V
73V
500ms, 80ms / 230VAC at rated power
180 ~ 295VAC          254 ~ 417VDC
47 ~ 63Hz
Total harmonic distortion will be lower than 20% when output loading is 75% or higher
92%
<0.5mA / 240VAC
Compliance to EN55015, EN61000-3-2 Class C(
40% rated power) ; EN61000-3-3
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61547 light industry level (surge 2KV),  criteria A
-30 ~ +60
 (Refer to "Derating Curve")
20 ~ 90% RH non-condensing
-40 ~ +80
, 10 ~ 95% RH
±
0.03%/
 (0 ~ 50
)
10 ~ 500Hz, 2G 10min./1cycle, period for  60min. each along X, Y, Z axes
260.6K hrs min.      MIL-HDBK-217F (25
)
123.5*81.5*23mm (L*W*H)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25  of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf parallel capacitor.
3. Please see "DIP switch table".
4. Derating may be needed under low input voltage. Please check the static characteristics for more details.
5. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
6. Efficiency is measured at 900mA/67V output set by DIP switch.
7. No load power consumption<1W is measured at 180 277VAC, with lighting fixture connected and output current dimmed to 0%.
~
8. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the 
    complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
9. To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED power supply can only be used behind a switch without permanently 
    connected to the mains.
0.24Kg ; 54pcs/15Kg/1.12CUFT
60W Multiple-Stage Output Current LED Power Supply
Output current level selectable by DIP S.W.
180~295VAC input only
Built-in active PFC function
Protections: Short circuit / Over voltage / Over temperature
Cooling by free air convection
Fully isolated plastic case
Class   power unit, no FG
Built-in 0~10Vdc and PWM signal dimming function
Built-in 12V/50mA auxiliary output
Logarithm or linear dimming curve selectable(Meet IEC62386-207)
Temperature compensation function by external NTC
No load power consumption <1W(Note.7)
Power supplies synchronization function up to 10 units
Suitable for indoor LED lighting applications
3 years warranty
 Features :
L C M - 6 0  
s e r i e s
RIPPLE & NOISE (max.)  
Note.2
NO LOAD OUTPUT VOLTAGE (max.)
ENVIRONMENT
SAFETY &
FUNCTION
EMC
PROTECTION
16ms/230VAC at rated power
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3.75KVAC
UL8750, ENEC EN61347-1, EN61347-2-13, EN62384 independent approved 
I/P-O/P:>100M Ohms / 500VDC / 25
/ 70% RH
File Name:LCM-60-SPEC   2014-01-07
SELECTABLE CURRENT 
Note.3
500mA
700mA
600mA
900mA
1050mA
1400mA
±5.0%
CURRENT ACCURACY
EMC IMMUNITY
EMC EMISSION
SELV
F
M
M
110
SHORT CIRCUIT      
OVER VOLTAGE           
 
OVER TEMPERATURE
AUXILIARY POWER
TEMP. COMPENSATION
SYNCHRONIZATION
Constant current limiting, recovers automatically after fault condition is removed
Protection type : Shutdown o/p voltage, re-power on to recover
105 ~ 125V
Shut down o/p voltage, re-power on to recover
12V @ 50mA for driving fan; Tolerance
5%
±
By external NTC(not provide with the power supply), please see "Temperature Compensation Operation"
Please see "Synchronization Operation"
DIMMING
Please see "Dimming Operation"
0.32A/230VAC          0.27A/277VAC
RIPPLE CURRENT
PF
0.975/230VAC, PF
0.96/277VAC at rated power  (Please refer to "Power Factor Characteristic" curve)
COLD START 20A(t
=270  s measured at 50% I
) at 230VAC 
width
peak
μ