SPECIFICATION
MODEL
DC VOLTAGE
RATED CURRENT
RATED POWER
OUTPUT
VOLTAGE ADJ. RANGE
Note.6
CURRENT ADJ. RANGE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
Note.8
HOLD UP TIME (Typ.)
VOLTAGE RANGE
Note.5
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INPUT
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
SAFETY STANDARDS
Note.7
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSION
OTHERS
NOTE
PACKING
OVER CURRENT
Note.4
OVER VOLTAGE
OVER TEMPERATURE
Can be adjusted by internal potentiometer A type only
16ms at full load     230VAC /115VAC
90 ~ 305VAC          127 ~ 431VDC
47 ~ 63Hz
PF>0.96/115VAC, PF>0.96/230VAC, PF>0.94/277VAC at full load (Please refer to "Power Factor Characteristic" curve)
0.85A / 115VAC          0.425A / 230VAC          0.4A / 277VAC
COLD START 70A(twidth=485 s measured at 50% Ipeak) at 230VAC
μ
<0.75mA / 277VAC
95 ~ 108%
Protection type : Constant current limiting, recovers automatically after fault condition is removed
Compliance to EN55015, EN61000-3-2  Class C ( 60% load) ; EN61000-3-3
Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024, light industry level (surge 4KV),  criteria A
20 ~ 95% RH non-condensing
-40 ~ +80
, 10 ~ 95% RH
±
0.03%/
(0 ~ 60
)
10 ~ 500Hz, 5G 12min./1cycle, period for  72min. each along X, Y, Z axes
UL8750, CSA C22.2 No. 250.0-08(except for HLG-80H-48/54V & HLG-80H-48/54BL), UL8750 listed for HLG-80H-
BL
EN61347-1, EN61347-2-13 independent
approved ; Design refer to UL60950-1, TUV EN60950-1
, J61347-1, J61347-2-13, IP65 or IP67
357.8Khrs min.      MIL-HDBK-217F (25
)
195.6*61.5*38.8mm (L*W*H)
0.84Kg; 16pcs/14.4Kg/0.54CUFT
Protection type : Shut down o/p voltage, re-power on to recover
80W Single Output Switching Power Supply
Universal AC input / Full range (up to 305VAC)
Built-in active PFC function
Protections: Short circuit / Over current / Over voltage / Over temperature
Cooling by free air convection
OCP point adjustable through output cable or internal potentiometer
IP67 / IP65 design for indoor or outdoor installations
"UL8750 listed" safety approved for HLG-80H- BL
Class 2 power unit
Three in one dimming function (1~10Vdc or PWM signal or resistance)
Suitable for LED lighting and moving sign applications
Compliance to worldwide safety regulations for lighting
Suitable for dry / damp / wet locations
5 years warranty (Note.10)
Features :
H L G - 8 0 H
s e r i e s
RIPPLE & NOISE (max.)
Note.2
VOLTAGE TOLERANCE
Note.3
ENVIRONMENT
SAFETY &
EMC
PROTECTION
Shut down o/p voltage, re-power on to recover
Blank : IP67 rated. Cable for I/O connection.
14 ~ 17V
59 ~ 68V
88%
89%
90%
90.5%
91%
91%
91%
91%
91%
±2.5%
3 ~ 5A
±2.0%
3 ~ 5A
±1.0%
2.4 ~ 4A
±1.0%
2.04 ~ 3.4A
±1.0%
1.62 ~ 2.7A
±1.0%
1.38 ~ 2.3A
±1.0%
1.02 ~ 1.7A
±0.5%
±0.5%
±0.5%
±0.5%
±0.5%
±0.5%
±0.5%
±2.0%
±1.5%
±1.0%
±0.5%
±0.5%
±0.5%
±0.5%
±1.0%
0.9 ~ 1.5A
±0.5%
±0.5%
±1.0%
1.17 ~ 1.95A
±0.5%
±0.5%
12V
HLG-80H-12
HLG-80H-15
HLG-80H-20
HLG-80H-24
HLG-80H-30
HLG-80H-36
HLG-80H-42
HLG-80H-48
HLG-80H-54
7.2 ~12V
15V
9 ~ 15V
20V
12 ~ 20V
24V
14.4 ~ 24V
30V
18 ~ 30V
36V
21.6 ~ 36V
48V
28.8 ~ 48V
5A
5A
4A
3.4A
2.7A
2.3A
1.7A
60W
75W
80W
81.6W
81W
82.8W
81.6W
150mVp-p
150mVp-p
13.5 ~ 17V
150mVp-p
17 ~ 22V
150mVp-p
22 ~ 27V
200mVp-p
27 ~ 33V
200mVp-p
33 ~ 40V
200mVp-p
43 ~ 53V
10.8 ~ 13.5V
54V
32.4 ~ 54V
1.5A
81W
200mVp-p
49 ~ 58V
42V
25.2 ~ 42V
1.95A
81.9W
200mVp-p
38 ~ 46V
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3.75KVAC     I/P-FG:2KVAC     O/P-FG:1.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25
/ 70% RH
CONSTANT CURRENT REGION
Note.4
HLG-80H-12 A
A : IP65 rated. Output voltage and constant current level can be adjusted through internal potentiometer.
B : IP67 rated. Constant current level adjustable through output cable with 1~10Vdc or 10V PWM signal or resistance.
BL
:
(option)   Contact MEAN WELL for details.
D (option) : IP67 rated. Timer dimming function, contact MEAN WELL for details.
-40 ~ +70
(Refer to "Derating Curve")
EMC IMMUNITY
EMC EMISSION
SHORT CIRCUIT
Hiccup mode, recovers automatically after fault condition is removed
SELV
IP65 IP67
F
M
M
110
(for HLG-80H-12~42BL only)
(for HLG-80H-48/54BL only)
(for HLG-80H-48/54 only)
(except for BL type)
(except for HLG-80H-48/54)
(except for HLG-80H-48/54BL)
18 ~ 24V
23 ~ 30V
28 ~ 35V
35 ~ 43V
41 ~ 49V
54 ~ 63V
48 ~ 58V
THD< 20% when output loading 60% at 115VAC/230VAC input and output loading 75% at 277VAC input
TOTAL HARMONIC DISTORTION
1200ms,80ms/115VAC    500ms,80ms/230VAC at full load ; B type 1200ms,200ms/115VAC   500ms,200ms/230VAC at 95% load
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25
of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Please refer to "DRIVING METHODSOF LED MODULE".
5. Derating may be needed under low input voltages. Please check the static characteristics for more details.
6. A type only.
7. Safety and EMC design refer to EN60598-1, CNS15233, GB7000.1, FCC part18.
8. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
9. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be
affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
10. Refer to warranty statement.
11. To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED power supply can only be used behind a switch without