MEAN WELL LED driverLED-switching power supply LCM-40DA LCM-40DA Data Sheet
Product codes
LCM-40DA
SPECIFICATION
MODEL
LCM-40DA
DC VOLTAGE RANGE
RATED POWER
OUTPUT
SETUP, RISE TIME
Note.5
HOLD UP TIME (Typ.)
VOLTAGE RANGE
Note.4
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
Note.6
AC CURRENT (Typ.)
INPUT
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
SAFETY STANDARDS
DALI STANDARDS
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSION
OTHERS
NOTE
PACKING
2 ~ 100V
2 ~ 67V
2 ~ 80V
2 ~ 57V
2 ~ 45V
2 ~ 40V
42W
700mVp-p
110V
65V
500ms, 80ms / 230VAC at
rated power
180 ~ 295VAC 254 ~ 417VDC
47 ~ 63Hz
91%
Compliance to EN55015, EN61000-3-2 Class C(
40%
) ; EN61000-3-3;
≧
rated power
GB17625.1,GB17743
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61547 light industry level (surge 2KV), criteria A
-30 ~ +60
(Refer to "Derating Curve")
℃
20 ~ 90% RH non-condensing
-40 ~ +80
, 10 ~ 95% RH
℃
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
193.6K hrs min. MIL-HDBK-217F (25
)
℃
123.5*81.5*23mm (L*W*H)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
℃
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf parallel capacitor.
3. Please see "DIP switch table".
4. Derating may be needed under low input voltage. Please check the static characteristics for more details.
5. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
6. Efficiency is measured at 500mA/80V output set by DIP switch.
7. No load power consumption<0.5W(LCM-40DA) and <1.2W(LCM-40DA-AUX) is measured at 180 277VAC, with lighting fixture connected and output
~
current dimmed to 0%.
8. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
0.24Kg ; 54pcs/15Kg/1.12CUFT
40W Multiple-Stage Output Current LED Power Supply
LCM-40DA
series
RIPPLE & NOISE (max.)
Note.2
NO LOAD OUTPUT VOLTAGE (max.)
ENVIRONMENT
SAFETY &
FUNCTION
EMC
PROTECTION
16ms/230VAC at
rated power
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3.75KVAC
UL8750, ENEC EN61347-1, EN61347-2-13, EN62384 independent, GB19510.14,GB19510.1 approved
Comply with IEC62386-101, 102, 207
I/P-O/P:>100M Ohms / 500VDC / 25
/ 70% RH
℃
File Name:LCM-40DA-SPEC 2014-10-27
SELECTABLE CURRENT
Note.3
350mA
600mA
500mA
700mA
900mA
1050mA
CURRENT ACCURACY
EMC IMMUNITY
EMC EMISSION
SHORT CIRCUIT
OVER VOLTAGE
OVER TEMPERATURE
AUXILIARY POWER (optional)
TEMP. COMPENSATION
SYNCHRONIZATION
Constant current limiting, recovers automatically after fault condition is removed
Shut down o/p voltage, re-power on to recover
Please see "Synchronization Operation"
DIMMING
Please see "Dimming Operation"
Protection type : Shutdown o/p voltage, re-power on to recover
110 ~ 130V
12V @ 50mA for driving fan; Tolerance 5%
±
By external NTC(not provide with the power supply), please see "Temperature compensation operation"
TOTAL HARMONIC DISTORTION Total harmonic distortion will be lower than 20% when output loading is 75% or higher
<0.5mA / 240VAC
0.23A/230VAC 0.2A/277VAC
RIPPLE CURRENT
Output current level selectable by DIP S.W.
180~295VAC input only
Built-in active PFC function
Protections: Short circuit / Over voltage / Over temperature
Cooling by free air convection
Fully isolated plastic case
Ⅱ
Class power unit, no FG
Built-in DALI interface and push dimming function
Optional 12V/50mA auxiliary output (Model No.: LCM-40DA-AUX)
IP20 design
Logarithm or linear dimming curve selectable(Meet IEC62386-207)
Temperature compensation function by external NTC
No load power consumption <0.5W(<1.2W for LCM-40DA-AUX)(Note.7)
Power supplies synchronization function up to 10 units
Suitable for indoor LED lighting applications
3 years warranty
■
Features :
±5%
PF
0.975/230VAC, PF
0.96/277VAC at
(Please refer to "Power Factor Characteristic" curve)
≧
≧
rated power
COLD START 20A(t
=260 s measured at 50% I
) at 230VAC
width
peak
μ
SELV
F
M
M
110
±5%
±0.03%/ (0 ~ 50 )
℃
℃