SPECIFICATION
MDR-20-5
MDR-20-12
MDR-20-15
MDR-20-24
MODEL
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
OUTPUT
VOLTAGE ADJ. RANGE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
Note.5
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INPUT
INRUSH CURRENT (Typ.)
SAFETY STANDARDS
WORKING HUMIDITY
WORKING TEMP.
DC OK ACTIVE SIGNAL (max.)
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSION
OTHERS
NOTE
PACKING
OVERLOAD
OVER VOLTAGE
5V
12V
15V
24V
3A
1.67A
1.34A
1A
0 ~ 3A
0 ~ 1.67A
0 ~ 1.34A
0 ~ 1A
15W
20W
20W
24W
80mVp-p
120mVp-p
120mVp-p
13.5 ~ 16.5V
150mVp-p
21.6 ~ 26.4V
±2.0%
±1.0%
±1.0%
±1.0%
10.8 ~ 13.2V
4.75 ~ 5.5V
±1.0%
±1.0%
±1.0%
±1.0%
±1.0%
±1.0%
±1.0%
±1.0%
500ms, 30ms/230VAC          1000ms, 30ms/115VAC at full load
50ms/230VAC          20ms/115VAC at full load
85 ~ 264VAC          120 ~ 370VDC
47 ~ 63Hz
76%
80%
81%
84%
0.55A/115VAC          0.35A/230VAC
COLD START 20A/115VAC          40A/230VAC
105 ~ 160% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed
5.75 ~ 6.75V
3.75 ~ 6V / 50mA
Protection type : Shut down o/p voltage, re-power on to recover
13.8 ~ 16.2V
9 ~ 13.5V / 40mA
17.25 ~ 20.25V
11.5 ~ 16.5V / 40mA
27.6 ~ 32.4V
18 ~ 27V / 20mA
-20 ~ +70
(Refer to "Derating Curve")
20 ~ 90% RH non-condensing
-40 ~ +85
, 10 ~ 95% RH
±
0.03%/
(0 ~ 50
)
Component:10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6
236.9K hrs min.      MIL-HDBK-217F (25
)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
5. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
File Name:MDR-20-SPEC   2013-11-26
UL508, TUV EN60950-1 approved
Compliance to EN55011, EN55022 (CISPR22), EN61204-3 Class B, EN61000-3-2,-3
Compliance to EN61000-4-2, 3, 4, 5, 6, 8, 11, EN55024,EN61000-6-1,EN61204-3, light industry level, criteria A
20W Single Output Industrial DIN Rail Power Supply
MDR-20
series
RIPPLE & NOISE (max.)
Note.2
VOLTAGE TOLERANCE
Note.3
ENVIRONMENT
PROTECTION
SAFETY &
EMC
(Note 4)
WITHSTAND VOLTAGE
ISOLATION RESISTANCE

Universal AC input/Full range

Protections: Short circuit / Overload / Over voltage

Cooling by free air convection

Can be installed on DIN rail TS-35/7.5 or 15

Built in DC OK active signal

LED indicator for power on

No load power consumption<0.75W

100% full load burn-in test

3 years warranty
Features :
22.5*90*100mm (W*H*D)
0.19Kg; 72pcs/14.7Kg/0.91CUFT
..
LEAKAGE CURRENT
<1mA / 240VAC
FUNCTION
I/P-O/P:3KVAC     I/P-FG:2KVAC     O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25
/ 70% RH
EMC IMMUNITY
EMC EMISSION