Fujitsu FTR-B3SA4.5Z PCB Mount Relay FTR-B3SA4.5Z Data Sheet

Product codes
FTR-B3SA4.5Z
Page of 10
3
FTR-K1 SERIES
COIL RATING
FTR-B3 SERIES
Coil 
Code
Rated Coil 
Voltage 
(VDC)
Coil Resistance 
+/- 10% (Ohm)
Must Operate 
Voltage
    (VDC) *
Must Release 
Voltage
    (VDC) *
Max. Coil Voltage
(VDC)
Rated Power 
(mW)
1.5
1.5
16.1
1.13
0.15
3.53
140
003
3
64.3
2.25
0.3
7.05
4.5
4.5
145
3.38
0.45
10.58
006
6
257
4.5
0.6
14.10
009
9
579
6.75
0.9
21.15
012
12
1,028
9
1.2
28.20
024
24
2,504
18
2.4
56.40
230
Standard type
Latching type (1 coil)
Coil 
Code
Rated Coil 
Voltage 
(VDC)
Coil Resistance 
+/- 10% (Ohm)
Must Operate 
Voltage
    (VDC) *
Must Release 
Voltage
    (VDC) *
Max. Coil Voltage
(VDC)
Rated Power 
(mW)
1.5
1.5
22.5
1.13
-0.13
3.53
100
003
3
90
2.25
-2.25
7.05
4.5
4.5
203
3.38
-3.38
10.58
006
6
360
4.5
-4.5
14.10
009
9
810
6.75
-6.75
21.15
012
12
1,440
9
-9
28.20
024
24
4,800
18
-18
56.40
120
Type
Compliance
Contact rating
UL
UL 508
E 63615
Flammability: UL 94-V0 (plastics)
0.5A, 125VAC (resistive)
1A, 30VDC (resistive)
0.3A, 110VDC (resistive)
2A, 30VDC (resistive)
CSA
C22.2 No. 14
LR 40304-58
SAFETY STANDARDS
Note: All values in the table are valid for 20°C and zero contact current.
* Specified operate values are valid for pulse wave voltage.