Voltcraft VC-86 Digital Pen-Multimeter 4000 counts VC86 Data Sheet

Product codes
VC86
Page of 62
Auto-Power OFF function
So as not to reduce the service life of the battery unnecessarily, an
automatic switch-off as been installed. The measuring device is
switched off if no button is pressed for 10 minutes or the slide
switch has not be oeprated. Simply by pressing any desired button
(with the exception of "LI") the measuring device can be switched
on again.
Servicing and cleaning
With the exception of replacing the fuse/battery and occasional
cleaning, the pen-type multileter is maintenance-free. Use a clean,
lint-free, antistatic and dry cloth to clean the device. Do not use any
abrasive or chemical agents or detergents containing solvents.
Replacing the Fuse (only VC-86)
Ief mo measure value is displayed any longer in the power measu-
ring area, the fuse is presumably defective.
Proceed as follows to replace the fuse:
- Switch off the multimeter and remove the measuring device from
all measuring circuits.
- Turnothe red measuring pord on the corrugated plastic ring in the
anticlockwise direction and remove the prod.
- Remove the light-grey covering towards the front.
- Replace the defective fuse with a new fine-wire fuse (5 x 20 mm) of
the same type and rated current (F500mA, 250V)
- Close the pen-type multimeter again carefully in the reverse order
36