APC MGE Galaxy 3000 GLTT10KL User Manual

Product codes
GLTT10KL
Page of 4
Standard Features
Double Conversion
On-line topology
Input Power Factor Correction 
(IGBT rectifier)
Input Distortion Management
Step Load Voltage Stabilization
Intelligent Battery Management    
System
Fault Tolerant Architecture
Scalable Architecture 
(10 & 20 kVA models)
Integrated maintenance bypass
(Single Module only)
Dry contact I/O card
Casters with stabilizing feet
Color graphic display
with multilingual user
interface
Bottom or top entry
Three communications slots
Common Options 
(Single or Parallel)
Integrated Battery Bank
Dual Input 
Remote Alarm Status Panel (RASP)
Remote Summary Alarm Panel (RSAP)
Advanced power management software
Network Management Card/Web SNMP
RS232, RS485 and dry contacts
IBM AS400 Interface
RemotePowerMonitoring
Single Module Options
Matching power distribution 
unit (24 or 42 pole)
External maintenance bypass
Input isolation transformer
Parallel Module Options
2CB or 3CB System Bypass Cabinet
2 to 4CB secondary UPS Isolation
Circuit Breaker
System Bypass Distribution up to
84 pole
Remote Alarm Status Panel (RASP)
– 2/3/4 Module
Galaxy 3000
Technical Specifications
UPS Rating kVA/KW
10/8
15/12
20/16
30/24
Input
Voltage
208V, 220V, 480V, 600V, 3 Phase, 
4 Wire + G (+15%) (Parallel Module 208V only)
Frequency
60 Hz (+8/-25%)
Power Factor
<0.99
Current Distortion (THDI)
<3 %
Input Current (A @ 208V)
28
42
56
83
Output
Voltage
208V (220V, 480V, 600V w/aux cabinet), 3 Phase, 4 Wire + G (Parallel Module 208V only)
Frequency
60 Hz, ±1% (selectable to 4%), ±0.1% free running
Voltage Regulation
±1.0% for balanced load
±2.5% for 100% unbalanced load
Voltage Transient Response
±5% for 100% step load
±1% for loss or return of AC input
Voltage Recovery Time
Within 1% of nominal within 1 cycle
Voltage Distortion THD
<3% L-L and L-N for non-linear loads
Inverter Overload
120% for 1 min, 145% for 30 sec
Bypass Overload
10 x nominal current for 1 cycle
Output Current (A @ 208V)
28
42
56
83
Heat Rejection (BTUs) (@ 208V)
4821
7232
8895
13342
Environmental
Operating Temperature
UPS: 0° to 40°C (32°F to 104°F)
Battery: 25°C (77°F)
Non-Operating Temperature
–20°C to +45°C (–4°F to113°F)
Relative Humidity
0-95% non-condensing
Dimensions and Weights
W  x  D  X  H  in inches ( l b s . )
Single Module
UPS
Micro Cabinet
23.0”W X 35.5”D X 48.5”H (830 lbs max)
Standard Cabinet
32.8”W X 40.1”D X 62.4”H (2,565 lbs max)
Auxiliary Cabinet (matching Maintenance
18.8”W X 40.1”D X 62.4”H (450 lbs max)
Bypass, Output Transformer, Distribution)
Auxiliary Cabinet (42 Pole Distribution)
18.8”W X 40.1”D X 62.4”H (180 lbs max)
Battery Cabinet
33.0”W X 35.6”D X 62.4”H (2,723 lbs max)
Parallel Module
UPS (20/30kVA)
32.8”W X 40.1”D X 62.4”H (7565 lbs max)
System Bypass Cabinet
28.8”W X 35.64”D X 62.33”H (300 lbs max)
Distribution Cabinet
18.8”W X 35.64”D X 62.33”H (180 lbs max)
Standards
ISO 9001, UL 1778, cUL, UL924, FCC  Part 15, Subpart J, Class A, NEMA PE 1, 
NEMA 250, NFPA 70, IEC 1000 (801) level 4, OSHA
www.mgeups.com
info@mgeups.com
GX 3000
Revision 301
Effective:  November 2007
©MGE UPS SYSTEMS, Inc. All specifications subject to change without notice. The MGE UPS SYSTEMS logo is a trademark of MGE UPS SYSTEMS. 
MGE UPS SYSTEMS
1660 Scenic Avenue •  Costa Mesa, CA 92626
tel 
(800) 523-0142  •  (714) 557-1636
fax     (714) 557-9788
American Power Conversion
132 Fairgrounds Rd. •  West Kingston, RI 02892
tel
(401) 789-5735 ext 2128
fax
(401) 788-2782
T h e   C r i t i c a l   P o w e r   a n d   C o o l i n g   S e r v i c e s   B u s i n e s s   U n i t   o f   S c h n e i d e r   E l e c t r i c
Bypass
Input
(Optional)
Main
Input
KA2
KA1
Input
Fuses
Output
Fuses
Bypass
Static Switch
24 or
42 poles
To
Load
Battery
System
(External 
Cabinet
Optional)
(Isolation
Transformer
Optional)
QF1
~
=
Inverter
~
=
PFC
Rectifier
Output
Distribution
Cabinet
(Optional)
Internal
Maintenance
Bypass
Output
Static Switch
Maintenance
Bypass
Input
(Optional)
CB1
CB2
CB3 
(Optional)
Wraparound
Maintenance
Bypass
(Optional)
Output
Transformer
(Optional)
UPS
Cabinet
Q3BP
Q5M
Galaxy 3000 
Single Module
Single Line
Galaxy 3000 
Parallel Module 
Single Line