Sauter FK 100 Digital Force Gauge 100 N FK 100. User Manual

Product codes
FK 100.
Page of 3
 
 
 
 
Instruction Manual 
FK 
 
 
AS, 03.04.2008 
FK GB.doc 
Page 2 of 3 
S
S
T
 
 
5. 
Operation 
 
a. 
Display 
 
 
 
(1)  Measuring Result 
(2)  Measuring Units 
(3)  Measuring Direction 
(4)  Indication of PEAK Mode 
 
 
b. 
Operating keys 
 
ON / OFF:  
 
ON / OFF key 
(For ON, press 1 sec.) 
 
MAX:  
 
Changes  between  Track  and  Peak  mode  (capture  of 
maximum values) 
 
 
UNIT:  
 
Press short:  
 
Select unit: 
N, kg, lb, ou 
 
ZERO:  
 
 
Zeros the measuring result (Tara function) 
Cleans the peak value (in Peak mode) 
 
 
c. 
Display Return 
 
When the instrument itself is turned so that the head faces 
down, the display returns automatically.  
 
 
d. 
Measurement (Track Modus) 
 
Display  (1)  shows  the  continuous  force  in  a  defined 
direction (3)  
 
  
To zero the display, press:  
 
 
e. 
Peak-Hold Function (Peak Mode) 
 
Please press: 
 
 
6. 
Backside Fixing to a test stand 
 
Fixing by 4 x M3 scres. 
 
 
7. 
CE Declaration of Conformity  
 
 
 
 
 
 
 
(1) 
(2) 
(3) 
(4)