Tde Instruments 7400AS Data Sheet

Page of 8
2
Draft
Supply
2.6 - 3.4VDC
Current consumption
<10µA, 5µA typical. 
Reset Button
The 7400 has a Reset Button.
The 7401 does not.
Display
8 digit black LCD, 8mm characters
Count Range
99999999 - rollover to 0
Operating temperature
-10°C to +60°C
Storage temperature
-20°C to +60°C
Altitude
Up to 2000m
Relative Humidity
80% max up to 31°C, decreasing to 50%
max at 40°C
Specification
R
2
1 D +
Connections
Note:
This product is ideally suited to battery powered applications. Should the product be used
in a circuit where an external power source is used, then the complete system will require
separate approval to meet the CE standards.
D
+
R
+
1
2.6 - 3.4V
<= +18V
+
2
+
High Speed Count
(TTL/CMOS)
Low Speed Count 
(Contact Closure/
Open Collector)
External Reset
(Contact Closure/
Open Collector)
Direction
(TTL/CMOS)
This product can be powered from a higher
voltage DC supply using the external voltage
control circuit shown on page 7. 
up 
down 
internal
resistor
internal
resistor
internal
resistor
<=5KHz
<=18V
0.7V
=>100 S
µ
<=20Hz
<=18V
0.7V
=>25mS
<=18V
0.7V
<=18V
0.7V
=>15mS
740001.qxd  04/01/02  14:36  Page 2