32 
8  Data output RS 232 C 
8.1  Technical data 
 
  8-bit ASCII Code 
  1 start bit, 8 data bits, 1 stop bit, no parity bit 
  Baud rate selectable at 1200, 2400, 4800, 9600 and 19200 Baud   
  Miniature plug-in necessary (9 pole D-Sub) 
  For  operation  with  interface  faultless  operation  is  only  ensured  with  the  correct 
KERN 
– interface cable (max. 2m) 
8.2  Pin allocation of the balance output socket (front view) 
 
 
 
 
 
      1
 
 
                                    
9             6    
 
 
Pin 2: 
Transmit data 
Pin 3: 
Receive data 
Pin 5: 
Signal ground 
 
8.3  Explanation of the data transfer 
8.3.1  Pr PC 
Press the PRINT key, at stable weight the format is transferred from LAPR.  
 
a.  Format for stable values for weight/quantity/percentage 
10  11  12 
13  14  15  16  17 
18 
M
 
N
1
   N
2
   N
3
   N
4
   N
5
   N
6
   N
7
   N
8
   N
9
   N
10
   B 
U
1
   U
2
   U
3
   CR  LF 
 
b.  Format in case of fault  
10  11  12 
13  14  15  16  17 
18 
B   B   B   B   B   B   B   B   B   B   B   E  
r  
r  
o  
r  
CR 
 
LF